Background A teleoperation system for bevel-tipped flexible needle steering has been evaluated. Robotic systems have been exploited as the main tool to achieve high accuracy and reliability. However, for reasons of safety and acceptance by the surgical community, keeping the physician tightly in the loop is preferable. Methods The system uses ultrasound imaging, path planning, and control to compute the desired needle orientation during the insertion and intuitively passes this information to the operator, who teleoperates the motion of the needle's tip. Navigation cues about the computed orientation are provided through haptic and visual feedback to the operator to steer the needle. Results The targeting accuracy of several co-manipulation strategies were studied in four sets of experiments involving human subjects with clinical backgrounds. Conclusions Experimental results show that receiving feedback regarding the desired needle orientation improves the targeting accuracy by a factor of 9 with respect to manual insertions.

Abayazid, M., Pacchierotti, C., Moreira, P., Alterovitz, R., Prattichizzo, D., Misra, S. (2016). Experimental evaluation of co-manipulated ultrasound-guided flexible needle steering. THE INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 12(2), 219-230 [10.1002/rcs.1680].

Experimental evaluation of co-manipulated ultrasound-guided flexible needle steering

Pacchierotti, C.;Prattichizzo, D.;
2016-01-01

Abstract

Background A teleoperation system for bevel-tipped flexible needle steering has been evaluated. Robotic systems have been exploited as the main tool to achieve high accuracy and reliability. However, for reasons of safety and acceptance by the surgical community, keeping the physician tightly in the loop is preferable. Methods The system uses ultrasound imaging, path planning, and control to compute the desired needle orientation during the insertion and intuitively passes this information to the operator, who teleoperates the motion of the needle's tip. Navigation cues about the computed orientation are provided through haptic and visual feedback to the operator to steer the needle. Results The targeting accuracy of several co-manipulation strategies were studied in four sets of experiments involving human subjects with clinical backgrounds. Conclusions Experimental results show that receiving feedback regarding the desired needle orientation improves the targeting accuracy by a factor of 9 with respect to manual insertions.
2016
Abayazid, M., Pacchierotti, C., Moreira, P., Alterovitz, R., Prattichizzo, D., Misra, S. (2016). Experimental evaluation of co-manipulated ultrasound-guided flexible needle steering. THE INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 12(2), 219-230 [10.1002/rcs.1680].
File in questo prodotto:
File Dimensione Formato  
rcs.1680.pdf

non disponibili

Tipologia: PDF editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 3.45 MB
Formato Adobe PDF
3.45 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.