Measurement results to validate the UTD triple diffraction coefficient are presented. The experimental setup consists of multiple metallic objects, with triangular and rectangular profiles, located inside an anechoic chamber and illuminated by a sector antenna to reproduce a spherical wavefront with a transverse electromagnetic (TEM) incident field. Another sector antenna is moved vertically to collect electromagnetic fields across the second order UTD Incident Shadow Boundaries and in the triple diffraction transition region. The measured and theoretical fields are compared using a free space normalization. Such comparison is also validated by calculating the mean error, the standard deviation, and root mean square error that occur between the theoretical model and the measured field. The results show excellent agreement between the theoretical third order UTD solution, employing the novel triple diffraction coefficient, and the experimental results. © 1963-2012 IEEE.
Negishi, T., Picco, V., Spitzer, D., Erricolo, D., Carluccio, G., Puggelli, F., et al. (2014). Measurements to validate the UTD triple diffraction coefficient. IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 62(7), 3723-3730 [10.1109/TAP.2014.2318334].
Measurements to validate the UTD triple diffraction coefficient
CARLUCCIO, GIORGIO;PUGGELLI, FEDERICO;ALBANI, MATTEO
2014-01-01
Abstract
Measurement results to validate the UTD triple diffraction coefficient are presented. The experimental setup consists of multiple metallic objects, with triangular and rectangular profiles, located inside an anechoic chamber and illuminated by a sector antenna to reproduce a spherical wavefront with a transverse electromagnetic (TEM) incident field. Another sector antenna is moved vertically to collect electromagnetic fields across the second order UTD Incident Shadow Boundaries and in the triple diffraction transition region. The measured and theoretical fields are compared using a free space normalization. Such comparison is also validated by calculating the mean error, the standard deviation, and root mean square error that occur between the theoretical model and the measured field. The results show excellent agreement between the theoretical third order UTD solution, employing the novel triple diffraction coefficient, and the experimental results. © 1963-2012 IEEE.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11365/983254
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo