Calorimetry plays an essential role in experiments observing high energy gamma and cosmic rays in space. The observational capabilities are mainly limited by the geometrical dimensions and the mass of the calorimeter. Since deployable mass depends on the design of the detector and the total mass of the payload, it is important to optimize the geometrical acceptance of the calorimeter for rare events, its granularity for particle identification, and its absorption depth for the measurement of the particle energy. A design of a calorimeter that could simultaneously optimize these characteristics assuming a mass limit of about 1.6 t has been studied. As a result, a homogeneous calorimeter instrumented with cesium iodide (CsI) crystals was chosen as the best compromise given the total mass constraint. The most suitable geometry found is cubic and isotropic, so as to detect particles arriving from every direction in space, thus maximizing the acceptance; granularity is obtained by filling the cubic volume with small cubic CsI crystals. The total radiation length in any direction is very large, and allows for optimal electromagnetic particle identification and energy measurement, while the interaction length is at least sufficient to allow a precise reconstruction of hadronic showers. Optimal values for the size of the crystals and spacing among them have been studied. Two prototypes have been constructed and preliminary tests with high energy ion and muon beams are reported.
Mori, N., Adriani, O., Basti, A., Bigongiari, G., Bonechi, L., Bonechi, S., et al. (2013). Homogeneous and isotropic calorimetry for space experiments. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 732, 311-315 [10.1016/j.nima.2013.05.138].
Homogeneous and isotropic calorimetry for space experiments
Bigongiari, G.;Bonechi, S.;Brogi, P.;Maestro, P.;Marrocchesi, P. S.;Sulaj, A.;Vannuccini, E.
2013-01-01
Abstract
Calorimetry plays an essential role in experiments observing high energy gamma and cosmic rays in space. The observational capabilities are mainly limited by the geometrical dimensions and the mass of the calorimeter. Since deployable mass depends on the design of the detector and the total mass of the payload, it is important to optimize the geometrical acceptance of the calorimeter for rare events, its granularity for particle identification, and its absorption depth for the measurement of the particle energy. A design of a calorimeter that could simultaneously optimize these characteristics assuming a mass limit of about 1.6 t has been studied. As a result, a homogeneous calorimeter instrumented with cesium iodide (CsI) crystals was chosen as the best compromise given the total mass constraint. The most suitable geometry found is cubic and isotropic, so as to detect particles arriving from every direction in space, thus maximizing the acceptance; granularity is obtained by filling the cubic volume with small cubic CsI crystals. The total radiation length in any direction is very large, and allows for optimal electromagnetic particle identification and energy measurement, while the interaction length is at least sufficient to allow a precise reconstruction of hadronic showers. Optimal values for the size of the crystals and spacing among them have been studied. Two prototypes have been constructed and preliminary tests with high energy ion and muon beams are reported.File | Dimensione | Formato | |
---|---|---|---|
NIMA732_311.pdf
non disponibili
Tipologia:
Post-print
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
1.61 MB
Formato
Adobe PDF
|
1.61 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11365/45052
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo