This paper reports the results of a study performed to develop a rapid and straightforward chromatographic method for the identification and quantification of trans-resveratrol in commercial trans-resveratrol-containing dietary supplements. The method employs an Alltech Platinum EPS 100 A C-18 column operated under isocratic elution mode with a 70:30 (v/v) water-acetonitrile mixture as the mobile phase at flow rate of 1.0 mL min-1. Peak detection is performed at 306 nm with limit of detection (LOD) of 0.27 μg mL-1 and limit of quantification (LOQ) of 0.95 μg mL-1 and linear calibration graph within the concentration range of 2.63 to 10.53 μg mL-1. Other data related to the successful method validation include representative linear regression equation and correlation coefficient of the calibration graph for quantification of trans-resveratrol, as well as the results of replicate analysis of real samples and of a recovery study, carried out to evaluate precision and accuracy, respectively. The method is successfully applied to study the stability of trans-resveratrol in methanol solution under various storage conditions and to analyse commercial preparations of trans-resveratrol-containing dietary supplements.

Brizzi, V., Danilo, C., Brizzi, A. (2008). Identification and Quantification of Trans-Resveratrol in Dietary Supplements by a Rapid and Straightforward RP-HPLC Method. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 31, 2089-2100 [10.1080/10826070802225353].

Identification and Quantification of Trans-Resveratrol in Dietary Supplements by a Rapid and Straightforward RP-HPLC Method

BRIZZI, VITTORIO;BRIZZI, ANTONELLA
2008-01-01

Abstract

This paper reports the results of a study performed to develop a rapid and straightforward chromatographic method for the identification and quantification of trans-resveratrol in commercial trans-resveratrol-containing dietary supplements. The method employs an Alltech Platinum EPS 100 A C-18 column operated under isocratic elution mode with a 70:30 (v/v) water-acetonitrile mixture as the mobile phase at flow rate of 1.0 mL min-1. Peak detection is performed at 306 nm with limit of detection (LOD) of 0.27 μg mL-1 and limit of quantification (LOQ) of 0.95 μg mL-1 and linear calibration graph within the concentration range of 2.63 to 10.53 μg mL-1. Other data related to the successful method validation include representative linear regression equation and correlation coefficient of the calibration graph for quantification of trans-resveratrol, as well as the results of replicate analysis of real samples and of a recovery study, carried out to evaluate precision and accuracy, respectively. The method is successfully applied to study the stability of trans-resveratrol in methanol solution under various storage conditions and to analyse commercial preparations of trans-resveratrol-containing dietary supplements.
2008
Brizzi, V., Danilo, C., Brizzi, A. (2008). Identification and Quantification of Trans-Resveratrol in Dietary Supplements by a Rapid and Straightforward RP-HPLC Method. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 31, 2089-2100 [10.1080/10826070802225353].
File in questo prodotto:
File Dimensione Formato  
794834536_content.pdf

non disponibili

Tipologia: Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 237.3 kB
Formato Adobe PDF
237.3 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/24110
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo