A reduced scale prototype of the Pb–SciFi sampling e.m. calorimeter for the AMS-02 experiment was tested at CERN SPS beam line X5 at energies from 5 to . The detector was equalized with minimum ionizing particles and calibrated with electron beams. Effective sampling thickness, linearity and energy resolution were measured.
Cervelli, F., Chen, G., Coignet, G., DI FALCO, S., Falchini, E., Lomtadze, T., et al. (2002). A reduced scale e.m. calorimeter prototype for the AMS-02 experiment. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 490(1-2), 132-139 [10.1016/S0168-9002(02)00915-4].
A reduced scale e.m. calorimeter prototype for the AMS-02 experiment
MAESTRO, P.;MARROCCHESI, P. S.;PAOLETTI, R.;TURINI, N.;
2002-01-01
Abstract
A reduced scale prototype of the Pb–SciFi sampling e.m. calorimeter for the AMS-02 experiment was tested at CERN SPS beam line X5 at energies from 5 to . The detector was equalized with minimum ionizing particles and calibrated with electron beams. Effective sampling thickness, linearity and energy resolution were measured.File | Dimensione | Formato | |
---|---|---|---|