Objective: Ultrasonography (US) demonstrated to be a promising tool for the diagnosis of calcium pyrophosphate dihydrate deposition disease (CPPD). The aim of this systematic literature review (SLR) was to collect the definitions for the US elementary lesions and to summarize the available data about US diagnostic accuracy in CPPD. Methods: We systematically reviewed all the studies that considered US as the index test for CPPD diagnosis without restrictions about the reference test or that provided definitions about US identification of CPPD. Sensitivity and specificity were calculated for each study and definitions were extrapolated. Subgroup analyses were planned by anatomical site included in the index text and different reference standards. Results: Thirty-seven studies were included in this review. All the studies were eligible for the collection of US findings and all definitions were summarized. US description of elementary lesions appeared heterogeneous among the studies. Regarding US accuracy, 13 articles entered in the meta-analysis. Considering each joint structure, the sensitivity ranged between 0.77 (0.63-0.87) and 0.34 (0.16-0.58) while the specificity varies between 1.00 (0.89-1.00) and 0.92 (0.16-1.00). Considering the reference standards used, the sensibility ranged between 0.34 (0.02-0.65) and 0.87 (0.76-0.99) while specificity ranged between 0.84 (0.52-1.00) and 1.00 (0.99-1.00). Conclusion: US is potentially a useful tool for the diagnosis of CPPD but universally accepted definitions and further testing are necessary in order to assess the role of the technique in the diagnostic process.

Filippou, G., Adinolfi, A., Iagnocco, A., Filippucci, E., Cimmino, M.A., Bertoldi, I., et al. (2016). Ultrasound in the diagnosis of calcium pyrophosphate dihydrate deposition disease. A systematic literature review and a meta-analysis. OSTEOARTHRITIS AND CARTILAGE, 24(6), 973-981 [10.1016/j.joca.2016.01.136].

Ultrasound in the diagnosis of calcium pyrophosphate dihydrate deposition disease. A systematic literature review and a meta-analysis

FILIPPOU, GEORGIOS;DI SABATINO, VALENTINA;FREDIANI, BRUNO;
2016-01-01

Abstract

Objective: Ultrasonography (US) demonstrated to be a promising tool for the diagnosis of calcium pyrophosphate dihydrate deposition disease (CPPD). The aim of this systematic literature review (SLR) was to collect the definitions for the US elementary lesions and to summarize the available data about US diagnostic accuracy in CPPD. Methods: We systematically reviewed all the studies that considered US as the index test for CPPD diagnosis without restrictions about the reference test or that provided definitions about US identification of CPPD. Sensitivity and specificity were calculated for each study and definitions were extrapolated. Subgroup analyses were planned by anatomical site included in the index text and different reference standards. Results: Thirty-seven studies were included in this review. All the studies were eligible for the collection of US findings and all definitions were summarized. US description of elementary lesions appeared heterogeneous among the studies. Regarding US accuracy, 13 articles entered in the meta-analysis. Considering each joint structure, the sensitivity ranged between 0.77 (0.63-0.87) and 0.34 (0.16-0.58) while the specificity varies between 1.00 (0.89-1.00) and 0.92 (0.16-1.00). Considering the reference standards used, the sensibility ranged between 0.34 (0.02-0.65) and 0.87 (0.76-0.99) while specificity ranged between 0.84 (0.52-1.00) and 1.00 (0.99-1.00). Conclusion: US is potentially a useful tool for the diagnosis of CPPD but universally accepted definitions and further testing are necessary in order to assess the role of the technique in the diagnostic process.
2016
Filippou, G., Adinolfi, A., Iagnocco, A., Filippucci, E., Cimmino, M.A., Bertoldi, I., et al. (2016). Ultrasound in the diagnosis of calcium pyrophosphate dihydrate deposition disease. A systematic literature review and a meta-analysis. OSTEOARTHRITIS AND CARTILAGE, 24(6), 973-981 [10.1016/j.joca.2016.01.136].
File in questo prodotto:
File Dimensione Formato  
Ultrasound in the diagnosis of calcium pyrophosphate-Filippou-2016.pdf

non disponibili

Descrizione: Free full-text sul sito dell'editore - Elsevier Open Archive
Tipologia: PDF editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.11 MB
Formato Adobe PDF
1.11 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/998975