Abstract BACKGROUND: A 37-year-old man was referred for surgical treatment for a huge thoracic aortic aneurysm (90x80 mm) surrounding an endograft previously implanted in the thoracic aorta, During the procedure, massive haemoptysis ocourred with acute haemodynamic instability. INVESTIGATION: Physical examination, transthoracic echocardiography, thoracic and abdominal CT scan aortography. DIAGNOSIS: Haemodynamic instability and massive haemoptysis during a thoracic endovasoular aortic repair (TEVAR) procedure for a huge aortic aneursym. MANAGEMENT: TEVAR procedure, haemodynamic and respiratory support.

Tognarelli, A., Palmieri, C., Rizza, A., Troiani, R., Vaghetti, M., Mariani, M., et al. (2015). How should I treat a massive pulmonary haemorrhage secondary to a TEVAR procedure in a patient with a thoracic aortic aneurysm and a type B aortic dissection?. EUROINTERVENTION, 11(8), 963-964 [10.4244/EIJV11I8A196].

How should I treat a massive pulmonary haemorrhage secondary to a TEVAR procedure in a patient with a thoracic aortic aneurysm and a type B aortic dissection?

MURZI, MICHELE;DE DONATO, GIANMARCO;SETACCI, FRANCESCO;GALZERANO, GIUSEPPE;SETACCI, CARLO;
2015-01-01

Abstract

Abstract BACKGROUND: A 37-year-old man was referred for surgical treatment for a huge thoracic aortic aneurysm (90x80 mm) surrounding an endograft previously implanted in the thoracic aorta, During the procedure, massive haemoptysis ocourred with acute haemodynamic instability. INVESTIGATION: Physical examination, transthoracic echocardiography, thoracic and abdominal CT scan aortography. DIAGNOSIS: Haemodynamic instability and massive haemoptysis during a thoracic endovasoular aortic repair (TEVAR) procedure for a huge aortic aneursym. MANAGEMENT: TEVAR procedure, haemodynamic and respiratory support.
2015
Tognarelli, A., Palmieri, C., Rizza, A., Troiani, R., Vaghetti, M., Mariani, M., et al. (2015). How should I treat a massive pulmonary haemorrhage secondary to a TEVAR procedure in a patient with a thoracic aortic aneurysm and a type B aortic dissection?. EUROINTERVENTION, 11(8), 963-964 [10.4244/EIJV11I8A196].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/996497
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo