Interval plants are of interest in control theory as models of uncertain systems. They are useful because many worst-case analyses of these models are simple to carry out. For example, robust stability of an interval plant can be determined by investigating only the four Kharitonov vertices of the denominator polynomial. Also, the maximum peak of the Bode magnitude plot can be found using just 16 special plant vertices. These 16 vertices are connected by 32 special line segments. Most stability and frequency domain analyses that cannot be done using only the special vertices can be carried out using just the segments. From these results, it is tempting to conjecture that the 16 vertices or at least the 32 segments are adequate for step response analyses. This paper presents examples showing that these conjectures are not true.

Bartlett, A.C., Tesi, A., Vicino, A. (1992). Vertices and segments of interval plants are not sufficient for step response analysis. SYSTEMS & CONTROL LETTERS, 19(5), 365-370 [10.1016/0167-6911(92)90086-8].

Vertices and segments of interval plants are not sufficient for step response analysis

Vicino, Antonio
1992-01-01

Abstract

Interval plants are of interest in control theory as models of uncertain systems. They are useful because many worst-case analyses of these models are simple to carry out. For example, robust stability of an interval plant can be determined by investigating only the four Kharitonov vertices of the denominator polynomial. Also, the maximum peak of the Bode magnitude plot can be found using just 16 special plant vertices. These 16 vertices are connected by 32 special line segments. Most stability and frequency domain analyses that cannot be done using only the special vertices can be carried out using just the segments. From these results, it is tempting to conjecture that the 16 vertices or at least the 32 segments are adequate for step response analyses. This paper presents examples showing that these conjectures are not true.
1992
Bartlett, A.C., Tesi, A., Vicino, A. (1992). Vertices and segments of interval plants are not sufficient for step response analysis. SYSTEMS & CONTROL LETTERS, 19(5), 365-370 [10.1016/0167-6911(92)90086-8].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/9311
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo