The possibility of using quantitative ultrasound (QUS) in monitoring the response to antiresorptive drugs has yet to be defined. The aim of the present study was to evaluate whether heel ultrasonography, considering its characteristics of long-term precision, is able to monitor osteoporotic patients treated with alendronate. We studied 150 postmenopausal osteoporotic women (age 59.6 +/- 5.3 years) treated with alendronate and calcium (n = 74) or with calcium alone (n = 76) for 4 years. At baseline and after 12, 24, 36 and 48 months, we measured bone mineral density (BMD) at the lumbar spine by dual-energy X-ray absorptiometry (DXA, Hologic 4500), and speed of sound (SOS), broadband ultrasound attenuation (BUA) and Stiffness at the calcaneus by Achilles plus. Moreover, the longitudinal precision of QUS parameters was assessed by measuring 10 subjects once a month for 1 year and, on the basis of the coefficients of variation we obtained, we calculated the Least Significant Change between two measurements. In the alendronate-treated patients, at year 1, BMD increased by 4.2%, SOS by 0.4%, BUA by 1.1% and Stiffness by 3.2%; at year 2, BMD increased by 5.0%, SOS by 0.7%, BUA by 1.4% and Stiffness by 5.7%. At year 3, BMD increased by 6.2%, SOS by 0.9%, BUA by 1.8% and Stiffness by 7.6%. At the end of the study period, BMD increased by 7.6%, SOS by 1.2%, BUA by 1.9% and Stiffness by 9.0%. The minimal significant difference between two measurements was 0.8% for SOS, 5.6% for BUA and 5.0% for Stiffness. Among the QUS parameters, Stiffness showed the greatest total treatment effect and a longitudinal sensitivity which was only slightly lower than BMD. The MTI, which represents the period between scans required to show that a 'true' change has occurred, was 1.8, 2.7, 11.9 and 2.2 years for BMD, SOS, BUA and Stiffness respectively. Therefore, although the spinal BMD remains the optimal method, QUS at the heel, and in particular Stiffness, seems to be a sensitive tool for monitoring the response to alendronate.

Gonnelli, S., Cepollaro, C., Montagnani, A., Martini, S., Gennari, L., Mangeri, M., et al. (2002). Heel ultrasonography in monitoring alendronate therapy: a four-year longitudinal study. OSTEOPOROSIS INTERNATIONAL, 13(5), 415-421 [10.1007/s001980200048].

Heel ultrasonography in monitoring alendronate therapy: a four-year longitudinal study

GONNELLI, STEFANO;GENNARI, LUIGI;
2002-01-01

Abstract

The possibility of using quantitative ultrasound (QUS) in monitoring the response to antiresorptive drugs has yet to be defined. The aim of the present study was to evaluate whether heel ultrasonography, considering its characteristics of long-term precision, is able to monitor osteoporotic patients treated with alendronate. We studied 150 postmenopausal osteoporotic women (age 59.6 +/- 5.3 years) treated with alendronate and calcium (n = 74) or with calcium alone (n = 76) for 4 years. At baseline and after 12, 24, 36 and 48 months, we measured bone mineral density (BMD) at the lumbar spine by dual-energy X-ray absorptiometry (DXA, Hologic 4500), and speed of sound (SOS), broadband ultrasound attenuation (BUA) and Stiffness at the calcaneus by Achilles plus. Moreover, the longitudinal precision of QUS parameters was assessed by measuring 10 subjects once a month for 1 year and, on the basis of the coefficients of variation we obtained, we calculated the Least Significant Change between two measurements. In the alendronate-treated patients, at year 1, BMD increased by 4.2%, SOS by 0.4%, BUA by 1.1% and Stiffness by 3.2%; at year 2, BMD increased by 5.0%, SOS by 0.7%, BUA by 1.4% and Stiffness by 5.7%. At year 3, BMD increased by 6.2%, SOS by 0.9%, BUA by 1.8% and Stiffness by 7.6%. At the end of the study period, BMD increased by 7.6%, SOS by 1.2%, BUA by 1.9% and Stiffness by 9.0%. The minimal significant difference between two measurements was 0.8% for SOS, 5.6% for BUA and 5.0% for Stiffness. Among the QUS parameters, Stiffness showed the greatest total treatment effect and a longitudinal sensitivity which was only slightly lower than BMD. The MTI, which represents the period between scans required to show that a 'true' change has occurred, was 1.8, 2.7, 11.9 and 2.2 years for BMD, SOS, BUA and Stiffness respectively. Therefore, although the spinal BMD remains the optimal method, QUS at the heel, and in particular Stiffness, seems to be a sensitive tool for monitoring the response to alendronate.
2002
Gonnelli, S., Cepollaro, C., Montagnani, A., Martini, S., Gennari, L., Mangeri, M., et al. (2002). Heel ultrasonography in monitoring alendronate therapy: a four-year longitudinal study. OSTEOPOROSIS INTERNATIONAL, 13(5), 415-421 [10.1007/s001980200048].
File in questo prodotto:
File Dimensione Formato  
heel QUS oi 2002.pdf

non disponibili

Tipologia: Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 165.68 kB
Formato Adobe PDF
165.68 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/9233
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo