The absence of a simple and clinically practical method to determine whole blood viscosity can partly justify why the medical community has been slow in realizing the significance of whole blood viscosity. For this reason, the availability of a technique able to evaluate blood viscosity in a rapid and direct manner is welcome. To evaluate the feasibility in hemorheological laboratory of a new torsional oscillation viscometer, it was compared with a conventional cone–plate system. The viscosity comparison has been related to hematocrit value both on whole blood and suspended blood in a saline solution. The results showed a good repeatability and reproducibility of the new equipment, with a best-fitting data of the hematocrit 0–100% range characterized by coefficient of determinations, r2 > 0.95. Furthermore, a comparison of whole blood viscosity as measured by the two instruments was done on blood samples collected from hospitalized patients. Reasonable agreement for the viscosity values was found between the two methods with linear determination coefficients between the two measurement methods comprised between r2 = 0.7329 and 0.9263, depending on shear stress phase and the corresponding shear rate.
Travagli, V., Zanardi, I., Boschi, L., Gabbrielli, A., Mastronuzzi, V.M.A., Cappelli, R., et al. (2008). Comparison of blood viscosity using a torsional oscillation viscometer and a rheometer. CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 38(2), 65-74.
Comparison of blood viscosity using a torsional oscillation viscometer and a rheometer
Travagli, Valter;Zanardi, Iacopo;Boschi, Letizia;Gabbrielli, Alessandro;Cappelli, Roberto;Forconi, Sandro
2008-01-01
Abstract
The absence of a simple and clinically practical method to determine whole blood viscosity can partly justify why the medical community has been slow in realizing the significance of whole blood viscosity. For this reason, the availability of a technique able to evaluate blood viscosity in a rapid and direct manner is welcome. To evaluate the feasibility in hemorheological laboratory of a new torsional oscillation viscometer, it was compared with a conventional cone–plate system. The viscosity comparison has been related to hematocrit value both on whole blood and suspended blood in a saline solution. The results showed a good repeatability and reproducibility of the new equipment, with a best-fitting data of the hematocrit 0–100% range characterized by coefficient of determinations, r2 > 0.95. Furthermore, a comparison of whole blood viscosity as measured by the two instruments was done on blood samples collected from hospitalized patients. Reasonable agreement for the viscosity values was found between the two methods with linear determination coefficients between the two measurement methods comprised between r2 = 0.7329 and 0.9263, depending on shear stress phase and the corresponding shear rate.File | Dimensione | Formato | |
---|---|---|---|
CH1035.pdf
accesso aperto
Tipologia:
Pre-print
Licenza:
PUBBLICO - Pubblico con Copyright
Dimensione
124.17 kB
Formato
Adobe PDF
|
124.17 kB | Adobe PDF | Visualizza/Apri |
Clinical Hemorheology and Microcirculation 2008 65-74.pdf
non disponibili
Tipologia:
PDF editoriale
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
115.85 kB
Formato
Adobe PDF
|
115.85 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11365/8319
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo