An AC susceptometer operating in the range of 10 Hz to 100 kHz and at room temperature is designed, built, calibrated, and used to characterize the magnetic behaviour of coated magnetic nanoparticles. Other weakly magnetic materials (in amounts of some millilitres) can be analyzed as well. The setup makes use of a digital acquisition system in order to determine the amplitude and the phase of the sample magnetization as a function of the frequency of the driving magnetic field, which is powered by a digital waveform generator. A specific acquisition strategy makes the response directly proportional to the sample susceptibility, taking advantage of the differential nature of the coil assembly. A calibration method based on conductive samples is developed.

Alderighi, M., Bevilacqua, G., Biancalana, V., Khanbekyan, A., Dancheva, Y., Moi, L. (2013). A room-temperature alternating current susceptometer—Data analysis, calibration, and test. REVIEW OF SCIENTIFIC INSTRUMENTS, 84(12), 125105-1-125105-8 [10.1063/1.4842255].

A room-temperature alternating current susceptometer—Data analysis, calibration, and test

ALDERIGHI, MICHELE;BEVILACQUA, GIUSEPPE;BIANCALANA, VALERIO;KHANBEKYAN, ALEN;DANCHEVA, YORDANKA;MOI, LUIGI
2013-01-01

Abstract

An AC susceptometer operating in the range of 10 Hz to 100 kHz and at room temperature is designed, built, calibrated, and used to characterize the magnetic behaviour of coated magnetic nanoparticles. Other weakly magnetic materials (in amounts of some millilitres) can be analyzed as well. The setup makes use of a digital acquisition system in order to determine the amplitude and the phase of the sample magnetization as a function of the frequency of the driving magnetic field, which is powered by a digital waveform generator. A specific acquisition strategy makes the response directly proportional to the sample susceptibility, taking advantage of the differential nature of the coil assembly. A calibration method based on conductive samples is developed.
2013
Alderighi, M., Bevilacqua, G., Biancalana, V., Khanbekyan, A., Dancheva, Y., Moi, L. (2013). A room-temperature alternating current susceptometer—Data analysis, calibration, and test. REVIEW OF SCIENTIFIC INSTRUMENTS, 84(12), 125105-1-125105-8 [10.1063/1.4842255].
File in questo prodotto:
File Dimensione Formato  
RSI_sushi_pubblicato.pdf

non disponibili

Tipologia: Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 449.79 kB
Formato Adobe PDF
449.79 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/45963
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo