OBJECTIVE: To evaluate the x-ray appearance of Essure microinserts 5 years after their insertion. DESIGN: Prospective controlled study. SETTING: Tertiary referral centers for gynecologic care. PATIENT(S): Forty-five consecutive women with successful hysteroscopic bilateral placement of the Essure devices and postprocedure satisfactory hysterosalpingography confirmation test. INTERVENTION(S): Pelvic anteroposterior x-ray. MAIN OUTCOME MEASURE(S): Stability and and symmetric appearance of Essure microinsert positions; measurement of the intrauterine distance between the two devices. RESULT(S): After 5 years from their placement, no detachment nor fracture of devices was observed. x-Ray recognition of the device after 5 years showed findings similar to those recorded at 3 months' follow-through hysterosalpingography. CONCLUSION(S): x-Ray evaluation of findings related to stability of position, symmetric appearance, and distance between the two Essure microinserts corroborates the irreversibility and the reliability of the fibrotic reaction that ensured tubal occlusion after devices placement.
Franchini, M., Boeri, C., Calzolari, S., Imperatore, A., Cianferoni, L., Litta, P., et al. (2012). Essure transcervical tubal sterilization: a 5-year x-ray follow up. FERTILITY AND STERILITY, 95(6), 2114-2115 [10.1016/j.fertnstert.2011.02.022].
Essure transcervical tubal sterilization: a 5-year x-ray follow up
Imperatore, A.;Zerbetto, I.;Moncini, I.;Florio, P.
2012-01-01
Abstract
OBJECTIVE: To evaluate the x-ray appearance of Essure microinserts 5 years after their insertion. DESIGN: Prospective controlled study. SETTING: Tertiary referral centers for gynecologic care. PATIENT(S): Forty-five consecutive women with successful hysteroscopic bilateral placement of the Essure devices and postprocedure satisfactory hysterosalpingography confirmation test. INTERVENTION(S): Pelvic anteroposterior x-ray. MAIN OUTCOME MEASURE(S): Stability and and symmetric appearance of Essure microinsert positions; measurement of the intrauterine distance between the two devices. RESULT(S): After 5 years from their placement, no detachment nor fracture of devices was observed. x-Ray recognition of the device after 5 years showed findings similar to those recorded at 3 months' follow-through hysterosalpingography. CONCLUSION(S): x-Ray evaluation of findings related to stability of position, symmetric appearance, and distance between the two Essure microinserts corroborates the irreversibility and the reliability of the fibrotic reaction that ensured tubal occlusion after devices placement.File | Dimensione | Formato | |
---|---|---|---|
168 fertil&steril 2011-xray.pdf
non disponibili
Tipologia:
Post-print
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
58.88 kB
Formato
Adobe PDF
|
58.88 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11365/43934
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo