Gastrocolic fistula is one of the major complications of PEG caused by a technical defect or by a wrong indication for the procedure (ascitis, transillumination failure, visceral adhesions, bleeding, gastric ulceration). The incidence is 2 to 3%. The authors report a gastrocolic fistula discovered at the time of replacement of the original tube after six months of regular nutrition.

Di Cosmo, L., Piccolomini, A., Vuolo, G., Maglio, C., Ruggieri, G., Mariani, F., et al. (2000). Gastrocolic fistula after PEG: Case report [Fistola gastro-colica dopo PEG: caso clinico]. RIVISTA ITALIANA DI NUTRIZIONE PARENTERALE ED ENTERALE, 18(2), 77-79.

Gastrocolic fistula after PEG: Case report [Fistola gastro-colica dopo PEG: caso clinico]

Piccolomini A.;Ruggieri G.;
2000-01-01

Abstract

Gastrocolic fistula is one of the major complications of PEG caused by a technical defect or by a wrong indication for the procedure (ascitis, transillumination failure, visceral adhesions, bleeding, gastric ulceration). The incidence is 2 to 3%. The authors report a gastrocolic fistula discovered at the time of replacement of the original tube after six months of regular nutrition.
2000
Di Cosmo, L., Piccolomini, A., Vuolo, G., Maglio, C., Ruggieri, G., Mariani, F., et al. (2000). Gastrocolic fistula after PEG: Case report [Fistola gastro-colica dopo PEG: caso clinico]. RIVISTA ITALIANA DI NUTRIZIONE PARENTERALE ED ENTERALE, 18(2), 77-79.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/43840
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo