PURPOSE: To evaluate the intraoperative and postoperative performance of the single-piece AcrySof SA30AL intraocular lens (IOL) in a series of patients after cataract surgery and IOL implantation. SETTING: Department of Ophthalmology and Neurosurgery, University of Siena, Siena, Italy. METHODS: In this prospective study, 20 patients who had phacoemulsification and implantation of a single-piece AcrySof SA30AL lens from March to April 2000 were evaluated. Assessed were control of IOL folding, ease of IOL implantation, IOL centration, intraoperative and postoperative complications, visual acuity, and anterior (ACO) and posterior (PCO) capsule opacification. RESULTS: In all cases, the IOL was easily folded, inserted, and unfolded. It remained well centered in the capsular bag, and there were no intraoperative or postoperative complications. The best corrected visual acuity after surgery was 20/40 or better in all patients. No eye developed ACO or phimosis. One eye had a well-demarcated, oval area of lens epithelial cell proliferation on the posterior capsule that did not impair visual acuity. CONCLUSIONS: Initial results indicate that the single-piece AcrySof SA30AL IOL has good biocompatibility, haptic flexibility and resistance, and stability in the capsular bag. The incidence of PCO in 1 eye could have been the result of several factors and requires further evaluation. An area of future study is the wide haptic of the lens, which may create a path for cells to proliferate as they travel from the equatorial capsule

Caporossi, A., Casprini, F., Tosi, G.M., Baiocchi, S. (2002). Preliminary results of cataract extraction with implantation of a single-piece AcrySof intraocular lens. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 28(4), 652-655 [10.1016/S0886-3350(01)01121-X].

Preliminary results of cataract extraction with implantation of a single-piece AcrySof intraocular lens.

TOSI, GIAN MARCO;
2002-01-01

Abstract

PURPOSE: To evaluate the intraoperative and postoperative performance of the single-piece AcrySof SA30AL intraocular lens (IOL) in a series of patients after cataract surgery and IOL implantation. SETTING: Department of Ophthalmology and Neurosurgery, University of Siena, Siena, Italy. METHODS: In this prospective study, 20 patients who had phacoemulsification and implantation of a single-piece AcrySof SA30AL lens from March to April 2000 were evaluated. Assessed were control of IOL folding, ease of IOL implantation, IOL centration, intraoperative and postoperative complications, visual acuity, and anterior (ACO) and posterior (PCO) capsule opacification. RESULTS: In all cases, the IOL was easily folded, inserted, and unfolded. It remained well centered in the capsular bag, and there were no intraoperative or postoperative complications. The best corrected visual acuity after surgery was 20/40 or better in all patients. No eye developed ACO or phimosis. One eye had a well-demarcated, oval area of lens epithelial cell proliferation on the posterior capsule that did not impair visual acuity. CONCLUSIONS: Initial results indicate that the single-piece AcrySof SA30AL IOL has good biocompatibility, haptic flexibility and resistance, and stability in the capsular bag. The incidence of PCO in 1 eye could have been the result of several factors and requires further evaluation. An area of future study is the wide haptic of the lens, which may create a path for cells to proliferate as they travel from the equatorial capsule
2002
Caporossi, A., Casprini, F., Tosi, G.M., Baiocchi, S. (2002). Preliminary results of cataract extraction with implantation of a single-piece AcrySof intraocular lens. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 28(4), 652-655 [10.1016/S0886-3350(01)01121-X].
File in questo prodotto:
File Dimensione Formato  
Preliminary-results.pdf

non disponibili

Tipologia: Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 125.83 kB
Formato Adobe PDF
125.83 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/42507
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo