urpose: To investigate the applicability of flowable composites as post luting agents by assessing the push-out strength of posts. Methods: 36 intact single rooted human premolars were selected. The endodontic treatment was performed and half of the specimens were restored with light transmitting posts (DT Light Post Illusion) and the other half with opaque posts (Tech 21 X-OP). In both groups the following combinations of adhesive/cement were tested: OptiBond Solo Plus/Nexus Third Generation (NX3), XP Bond/SureFil SDR Flow (SDR), and Vertise Flow (VF). Push-out test was used to assess the retentive strength of fiber posts, which was expressed in megapascals (MPa). Specimens were analyzed under a stereomicroscope to determine failure mode (adhesive between luting agent and post, adhesive between luting agent and dentin or mixed failure). Push-out data and failure mode distribution were analyzed by two-way ANOVA and Chi-square test, respectively (P< 0.05). Results: The statistical analysis revealed that only the type of luting material significantly influenced push-out bond strength of the post (P< 0.001). SDR (9.00 ± 2.17 MPa) performed similarly to the control group NX3 (7.15 ± 1.74 MPa), while VF (4.81 ±1.51 MPa) should significantly lower bond strength. Failure modes differed significantly among groups.

Juloski, J., Goracci, C., Radovic, I., Chieffi, N., Vichi, A., Vulicevic, Z.r., et al. (2013). Post-retentive ability of new flowable resin composites. AMERICAN JOURNAL OF DENTISTRY, 26(6), 324-328.

Post-retentive ability of new flowable resin composites

JULOSKI, JELENA;GORACCI, CECILIA;CHIEFFI, NICOLETTA;VICHI, ALESSANDRO;FERRARI, MARCO
2013-01-01

Abstract

urpose: To investigate the applicability of flowable composites as post luting agents by assessing the push-out strength of posts. Methods: 36 intact single rooted human premolars were selected. The endodontic treatment was performed and half of the specimens were restored with light transmitting posts (DT Light Post Illusion) and the other half with opaque posts (Tech 21 X-OP). In both groups the following combinations of adhesive/cement were tested: OptiBond Solo Plus/Nexus Third Generation (NX3), XP Bond/SureFil SDR Flow (SDR), and Vertise Flow (VF). Push-out test was used to assess the retentive strength of fiber posts, which was expressed in megapascals (MPa). Specimens were analyzed under a stereomicroscope to determine failure mode (adhesive between luting agent and post, adhesive between luting agent and dentin or mixed failure). Push-out data and failure mode distribution were analyzed by two-way ANOVA and Chi-square test, respectively (P< 0.05). Results: The statistical analysis revealed that only the type of luting material significantly influenced push-out bond strength of the post (P< 0.001). SDR (9.00 ± 2.17 MPa) performed similarly to the control group NX3 (7.15 ± 1.74 MPa), while VF (4.81 ±1.51 MPa) should significantly lower bond strength. Failure modes differed significantly among groups.
2013
Juloski, J., Goracci, C., Radovic, I., Chieffi, N., Vichi, A., Vulicevic, Z.r., et al. (2013). Post-retentive ability of new flowable resin composites. AMERICAN JOURNAL OF DENTISTRY, 26(6), 324-328.
File in questo prodotto:
File Dimensione Formato  
Juloski post flowable.pdf

non disponibili

Tipologia: PDF editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 122.19 kB
Formato Adobe PDF
122.19 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/42120
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo