urpose: To investigate the applicability of flowable composites as post luting agents by assessing the push-out strength of posts. Methods: 36 intact single rooted human premolars were selected. The endodontic treatment was performed and half of the specimens were restored with light transmitting posts (DT Light Post Illusion) and the other half with opaque posts (Tech 21 X-OP). In both groups the following combinations of adhesive/cement were tested: OptiBond Solo Plus/Nexus Third Generation (NX3), XP Bond/SureFil SDR Flow (SDR), and Vertise Flow (VF). Push-out test was used to assess the retentive strength of fiber posts, which was expressed in megapascals (MPa). Specimens were analyzed under a stereomicroscope to determine failure mode (adhesive between luting agent and post, adhesive between luting agent and dentin or mixed failure). Push-out data and failure mode distribution were analyzed by two-way ANOVA and Chi-square test, respectively (P< 0.05). Results: The statistical analysis revealed that only the type of luting material significantly influenced push-out bond strength of the post (P< 0.001). SDR (9.00 ± 2.17 MPa) performed similarly to the control group NX3 (7.15 ± 1.74 MPa), while VF (4.81 ±1.51 MPa) should significantly lower bond strength. Failure modes differed significantly among groups.
Juloski, J., Goracci, C., Radovic, I., Chieffi, N., Vichi, A., Vulicevic, Z.r., et al. (2013). Post-retentive ability of new flowable resin composites. AMERICAN JOURNAL OF DENTISTRY, 26(6), 324-328.
Post-retentive ability of new flowable resin composites
JULOSKI, JELENA;GORACCI, CECILIA;CHIEFFI, NICOLETTA;VICHI, ALESSANDRO;FERRARI, MARCO
2013-01-01
Abstract
urpose: To investigate the applicability of flowable composites as post luting agents by assessing the push-out strength of posts. Methods: 36 intact single rooted human premolars were selected. The endodontic treatment was performed and half of the specimens were restored with light transmitting posts (DT Light Post Illusion) and the other half with opaque posts (Tech 21 X-OP). In both groups the following combinations of adhesive/cement were tested: OptiBond Solo Plus/Nexus Third Generation (NX3), XP Bond/SureFil SDR Flow (SDR), and Vertise Flow (VF). Push-out test was used to assess the retentive strength of fiber posts, which was expressed in megapascals (MPa). Specimens were analyzed under a stereomicroscope to determine failure mode (adhesive between luting agent and post, adhesive between luting agent and dentin or mixed failure). Push-out data and failure mode distribution were analyzed by two-way ANOVA and Chi-square test, respectively (P< 0.05). Results: The statistical analysis revealed that only the type of luting material significantly influenced push-out bond strength of the post (P< 0.001). SDR (9.00 ± 2.17 MPa) performed similarly to the control group NX3 (7.15 ± 1.74 MPa), while VF (4.81 ±1.51 MPa) should significantly lower bond strength. Failure modes differed significantly among groups.File | Dimensione | Formato | |
---|---|---|---|
Juloski post flowable.pdf
non disponibili
Tipologia:
PDF editoriale
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
122.19 kB
Formato
Adobe PDF
|
122.19 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11365/42120
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo