IRIS
We report on the properties of the Z resonance from 62500 Z decays into fermion pairs collected with the ALEPH detector at LEP, the Large Electron-Positron storage ring at CERN. We find M_Z =(91.193+/-0.016 (exp)+/-0.030 (LEP) ) GeV, Gamma-Z= (2497+/-31) MeV, sigma_had= (41+/-0.66) nb, and for the partial widths Gamma_vis= (489 +/- 24) MeV, Gamma_had= (1754 +/- 27) MeV, Gamma_ee=(85.0+/-1.6) MeV =(85.0±1.6)MeV, Gamma_mumu=(80+/-2.5) MeV and Gamma_tautau=(81.3+/-2.5) MeV, all in good agreement with the Standard Model. Assuming lepton universality and using a lepton sample without distinction of the final state we measure Gamma_ll=(84.3+/-1.3) MeV. The forward-backward asymmetry in leptonic decays is used to determine the vector and axial-vector weak coupling constants of leptors, g_v^ 2 ( (M_ Z) ^2 )=(0.12+/-0.12)x10^-2) and g_A^ 2 ( (M_ Z) ^2 )=0.2528 +/- 0.0040. The number of light neutrino species is N_nu =2.91+/- 0.13; the electroweak mixing angle is (sin(teta_ W ((M_ Z)^ 2 )))^2=0.2291+/-0.0040.
D., D., B., D., C., G., J. P., L., M. N., M., R., A., et al. (1990). Measurement of electroweak parameters from Z decays into fermion pairs. ZEITSCHRIFT FÜR PHYSIK. C, PARTICLES AND FIELDS, 48(3), 365-391 [10.1007/BF01572019].
Measurement of electroweak parameters from Z decays into fermion pairs
D. Decamp;B. Deschizeaux;C. Goy;J. P. Lees;M. N. Minard;R. Alemany;J. M. Crespo;M. Delfino;E. Fernandez;V. Gaitan;L.l. Garrido;P. Mato;R. Miquel;L.l. M. Mir;S. Orteu;A. Pacheco;J. A. Perlas;E. Tubau;M. G. Catanesi;D. Creanza;M. Palma;A. Farilla;G. Iaselli;G. Maggi;M. Maggi;S. Natali;S. Nuzzo;M. Quattromini;A. Ranieri;G. Raso;F. Romano;F. Ruggieri;G. Selvaggi;L. Silvestris;P. Tempesta;G. Zito;Y. Gao;H. Hu;D. Huang;S. Jin;J. Lin;T. Ruan;T. Wang;W. Wu;Y. Xie;D. Xu;R. Xu;J. Zhang;W. Zhao;H. Albrecht;W. B. Atwood;F. Bird;E. Blucher;G. Bonvicini;F. Bossi;J. Bourotte;D. Brown;T. H. Burnett;H. Drevermann;F. Dydak;R. W. Forty;C. Grab;R. Hagelberg;S. Haywood;B. Jost;M. Kasemann;G. Kellner;J. Knobloch;A. Lacourt;I. Lehraus;T. Lohse;D. Lüke;A. Marchioro;M. Martinez;J. May;S. Menary;A. Minten;A. Miotto;J. Nash;P. Palazzi;F. Ranjard;G. Redlinger;A. Roth;J. Rothberg;H. Rotscheidt;W. Rüden;R. S.t. Denis;D. Schlatter;M. Takashima;M. Talby;H. Taureg;W. Tejessy;H. Wachsmuth;S. Wasserbaech;S. Wheeler;W. Wiedenmann;W. Witzeling;J. Wotschack;Z. Ajaltouni;M. Bardadin Otwinowska;A. Falvard;R. El Fellous;P. Gay;P. Henrard;J. Jousset;B. Michel;J. C. Montret;D. Pallin;P. Perret;J. Proriol;F. Prulhière;J. D. Hansen;J. R. Hansen;P. H. Hansen;R. Møllerud;B. S. Nilsson;G. Petersen;I. Efthymiopoulos;E. Simopoulou;A. Vayaki;J. Badier;A. Blondel;G. Bonneaud;F. Braems;J. C. Brient;G. Fouque;A. Gamess;R. Guirlet;A. Rosowsky;A. Rougé;M. Rumpf;R. Tanaka;H. Videau;I. Videau;D. J. Candlin;G. Parrini;M. Corden;C. Georgiopoulos;M. Ikeda;J. Lannutti;D. Levinthal;M. Mermikides;L. Sawyer;G. Stimpfl;A. Antonelli;R. Baldini;G. Bencivenni;G. Bologna;P. Campana;G. Capon;V. Chiarella;B. D'Ettorre Piazzoli;G. Felici;P. Laurelli;G. Mannocchi;F. Massimo Brancaccio;F. Murtas;G. P. Murtas;G. Nicoletti;M. Pepe Altarelli;P. Picchi;P. Zografou;B. Altoon;O. Boyle;A. W. Halley;I. Have;J. L. Hearns;J. G. Lynch;W. T. Morton;C. Raine;J. M. Scarr;K. Smith;A. S. Thompson;B. Brandl;O. Braun;R. Geiges;C. Geweniger;P. Hanke;V. Hepp;E. E. Kluge;Y. Maumary;M. Panter;A. Putzer;B. Rensch;A. Stahl;K. Tittel;M. Wunsch;A. T. Belk;R. Beuselinck;D. M. Binnie;W. Cameron;M. Cattaneo;P. J. Dornan;S. Dugeay;A. M. Greene;J. F. Hassard;S. J. Patton;J. K. Sedgbeer;G. Taylor;I. R. Tomalin;A. G. Wright;P. Girtler;E. Kneringer;D. Kuhn;G. Rudolph;C. K. Bowdery;T. J. Brodbeck;A. J. Finch;F. Foster;G. Hughes;N. R. Keemer;M. Nuttall;B. S. Rowlingson;T. Sloan;S. W. Snow;T. Barczewski;L. A. T. Bauerdick;K. Kleinknecht;B. Renk;S. Roehn;H. G. Sander;M. Schmelling;F. Steeg;J. P. Albanese;J. J. Aubert;C. Benchouk;V. Bernard;A. Bonissent;D. Courvoisier;F. Etienne;S. Papalexiou;P. Payre;B. Puietrzyk;Z. Qian;W. Blum;P. Cattaneo;G. Cowan;B. Dehning;H. Dietl;M. Fernandez Bosman;M. Frank;A. Jahn;E. Lange;G. Lütjens;G. Lutz;W. Männer;H. G. Moser;Y. Pan;R. Richter;A. S. Schwarz;R. Settles;U. Stiegler;U. Stierlin;J. Thomas;V. Bertin;G. Bouard;J. Boucrot;O. Callot;X. Chen;A. Cordier;M. Davier;G. Ganis;J. F. Grivaz;P.h. Heusse;P. Janot;V. Journé;D. W. Kim;J. Lefrançois;A. M. Lutz;J. J. Veillet;Z. Zhang;F. Zomer;S. R. Amendolia;G. Bagliesi;G. Batignani;L. Bosisio;BOTTIGLI, UBALDO;C. Bradaschia;CIOCCI, MARIA AGNESE;I. Ferrante;F. Fidecaro;L. Foà;E. Focardi;F. Forti;A. Giassi;M. A. Giorgi;F. Ligabue;A. Lusiani;E. B. Mannelli;MARROCCHESI, PIER SIMONE;A. Messineo;F. Palla;G. Sanguinetti;J. Steinberger;R. Tenchini;G. Tonelli;G. Triggiani;J. M. Carter;M. G. Green;P. V. March;T. Medcalf;M. R. Saich;J. A. Strong;R. M. Thomas;T. Wildish;D. R. Botterill;R. W. Clifft;T. R. Edgecock;M. Edwards;S. M. Fisher;J. Harvey;T. J. Jones;P. R. Norton;D. P. Salmon;J. C. Thompson;B. Bloch Devaux;P. Colas;C. Klopfenstein;E. Lançon;E. Locci;S. Loucatos;L. Mirabito;E. Monnier;P. Perez;F. Perrier;J. Rander;J. F. Renardy;A. Roussarie;J. P. Schuller;J. G. Ashman;C. N. Booth;F. Combley;M. Dinsdale;J. Martin;D. Parker;L. F. Thompson;S. Brandt;H. Burkhardt;C. Grupen;H. Meinhard;E. Neugebauer;U. Schäfer;H. Seywerd;G. Apollinari;G. Giannini;B. Gobbo;F. Liello;E. Milotti;L. Rolandi;L. Bellantoni;J. F. Boudreau;D. Cinabro;J. S. Conway;D. F. Cowen;A. J. DeWeerd;Z. Feng;D. P. S. Ferguson;Y. S. Gao;J. L. Harton;J. Hilgart;J. E. Jacobsen;R. C. Jared;R. P. Johnson;B. W. LeClaire;Y. B. Pan;T. Parker;J. R. Pater;Y. Saadi;V. Sharma;J. A. Wear;F. V. Weber;Sau Lan Wu;G. Zobernig
1990-01-01
Abstract
We report on the properties of the Z resonance from 62500 Z decays into fermion pairs collected with the ALEPH detector at LEP, the Large Electron-Positron storage ring at CERN. We find M_Z =(91.193+/-0.016 (exp)+/-0.030 (LEP) ) GeV, Gamma-Z= (2497+/-31) MeV, sigma_had= (41+/-0.66) nb, and for the partial widths Gamma_vis= (489 +/- 24) MeV, Gamma_had= (1754 +/- 27) MeV, Gamma_ee=(85.0+/-1.6) MeV =(85.0±1.6)MeV, Gamma_mumu=(80+/-2.5) MeV and Gamma_tautau=(81.3+/-2.5) MeV, all in good agreement with the Standard Model. Assuming lepton universality and using a lepton sample without distinction of the final state we measure Gamma_ll=(84.3+/-1.3) MeV. The forward-backward asymmetry in leptonic decays is used to determine the vector and axial-vector weak coupling constants of leptors, g_v^ 2 ( (M_ Z) ^2 )=(0.12+/-0.12)x10^-2) and g_A^ 2 ( (M_ Z) ^2 )=0.2528 +/- 0.0040. The number of light neutrino species is N_nu =2.91+/- 0.13; the electroweak mixing angle is (sin(teta_ W ((M_ Z)^ 2 )))^2=0.2291+/-0.0040.
D., D., B., D., C., G., J. P., L., M. N., M., R., A., et al. (1990). Measurement of electroweak parameters from Z decays into fermion pairs. ZEITSCHRIFT FÜR PHYSIK. C, PARTICLES AND FIELDS, 48(3), 365-391 [10.1007/BF01572019].
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/41095
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.