PURPOSE: To compare the quality of vision with aspheric and spherical intraocular lenses (IOLs) in pseudophakic patients after long-term follow-up. METHODS: Two hundred eyes of 100 patients with bilateral cataracts were randomly assigned to receive spherical (Acrysof SN60AT [Alcon Laboratories Inc] or Sensar AR40e [Advanced Medical Optics Inc]) or aspheric IOLs (Acrysof SN60WF [Alcon] or Tecnis Z9000 [Advanced Medical Optics]). Ophthalmologic examination, including best spectacle-corrected visual acuity (BSCVA), pupil size, ocular dominance, contrast sensitivity under mesopic and photopic conditions, and wavefront analysis, was performed 2 months and 1 and 2 years after surgery. RESULTS: No statistically significant differences among the four groups in terms of age, pupil diameter, postoperative BSCVA, comeal spherical aberration, and posterior capsular opacification were noted. At all followup examinations, contrast sensitivity results showed no significant differences between the two aspheric IOLs at all spatial frequencies. Under photopic conditions, significant differences (P<.05) between spherical and aspheric IOLs were detected for spatial frequencies of 12 and 18 cycles per degree (cpd) at 2 months and 2 years and 12 cpd at 1 year. Under mesopic conditions, significant differences (P<.05) were detected between spherical and aspheric IOLs for all spatial frequencies at 2 months; all spatial frequencies except 18 cpd at 1 year; and spatial frequencies of 3, 12, and 18 cpd at 2 years. In addition, aspheric IOLs had statistical reductions in total spherical aberration at all follow-up examinations (P<.01). CONCLUSIONS: This study confirms that implantation of a modified aspheric IOL improves functional visual performance at 2 years postoperative

Caporossi, A., Casprini, F., Martone, G., Balestrazzi, A., Tosi, G.M., Ciompi, L. (2009). Contrast sensitivity evaluation of aspheric and spherical intraocular lenses 2 years after implantation. JOURNAL OF REFRACTIVE SURGERY, 25(7), 578-590 [10.3928/1081597X-20090610-03].

Contrast sensitivity evaluation of aspheric and spherical intraocular lenses 2 years after implantation.

CASPRINI, FABRIZIO;MARTONE, GIANLUCA;BALESTRAZZI, ANGELO;TOSI, GIAN MARCO;CIOMPI, LEONARDO
2009-01-01

Abstract

PURPOSE: To compare the quality of vision with aspheric and spherical intraocular lenses (IOLs) in pseudophakic patients after long-term follow-up. METHODS: Two hundred eyes of 100 patients with bilateral cataracts were randomly assigned to receive spherical (Acrysof SN60AT [Alcon Laboratories Inc] or Sensar AR40e [Advanced Medical Optics Inc]) or aspheric IOLs (Acrysof SN60WF [Alcon] or Tecnis Z9000 [Advanced Medical Optics]). Ophthalmologic examination, including best spectacle-corrected visual acuity (BSCVA), pupil size, ocular dominance, contrast sensitivity under mesopic and photopic conditions, and wavefront analysis, was performed 2 months and 1 and 2 years after surgery. RESULTS: No statistically significant differences among the four groups in terms of age, pupil diameter, postoperative BSCVA, comeal spherical aberration, and posterior capsular opacification were noted. At all followup examinations, contrast sensitivity results showed no significant differences between the two aspheric IOLs at all spatial frequencies. Under photopic conditions, significant differences (P<.05) between spherical and aspheric IOLs were detected for spatial frequencies of 12 and 18 cycles per degree (cpd) at 2 months and 2 years and 12 cpd at 1 year. Under mesopic conditions, significant differences (P<.05) were detected between spherical and aspheric IOLs for all spatial frequencies at 2 months; all spatial frequencies except 18 cpd at 1 year; and spatial frequencies of 3, 12, and 18 cpd at 2 years. In addition, aspheric IOLs had statistical reductions in total spherical aberration at all follow-up examinations (P<.01). CONCLUSIONS: This study confirms that implantation of a modified aspheric IOL improves functional visual performance at 2 years postoperative
2009
Caporossi, A., Casprini, F., Martone, G., Balestrazzi, A., Tosi, G.M., Ciompi, L. (2009). Contrast sensitivity evaluation of aspheric and spherical intraocular lenses 2 years after implantation. JOURNAL OF REFRACTIVE SURGERY, 25(7), 578-590 [10.3928/1081597X-20090610-03].
File in questo prodotto:
File Dimensione Formato  
Contrast-sensitivity.pdf

non disponibili

Tipologia: Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 476.64 kB
Formato Adobe PDF
476.64 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/36594
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo