PURPOSE: To evaluate early and 24-hour microtensile bond strength (microTBS) and the degree of conversion (DC) of one representative adhesive system from each of the four current bonding approaches. METHODS: 40 human molars were sectioned occluso-gingivally into two halves. Resin composite was bonded incrementally to flat, mid-coronal dentin, using the adhesives Adper Scotchbond MP (MP); Adper Scotchbond 2 (SB); Clearfil SE Bond (SE); and Adper Prompt L-Pop (LP) according to the respective manufacturer's instructions (n = 10). One half was immediately sectioned into sticks and subjected to muTBS test. As the sectioning process took approximately 1 hour, the results were designated as 1-hour bond strengths. The other half was stored in distilled water at 37 degrees C for 24 hours before being sectioned and tested. The DC of these systems was measured using Fourier Transform-Raman spectroscopy in three periods: immediately, 1 and 24 hours after polymerization. Data were analyzed with ANOVA and Tukey's tests. RESULTS: There were no significant differences between the 1-hour and 24-hour bond strengths (P > 0.05), or among the DC measured immediately, 1 hour and 24 hours after polymerization (P > 0.05). However, significant differences were observed among adhesives (P < 0.05). microTBS values obtained, in MPa (1 hour/24 hour), were: SB (48.6 + 1.3/48.4 + 3.5) = SE (51.9 + 4.7/53.3 +/- 2.9) > MP (35.3 +/- 10.9/38.6 + 6.7) > LP (25.5 + 1.1/26.0 + 1.5). The DC, in percentage (immediately/1 hour/24 hour), were: SE (81/82/87) > MP (79/77/81) > SB (60/63/65) > LP (39/37/42).

Sadek, F.t., Calheiros, F.c., Cardoso, P.e., Kawano, Y., Tay, F., Ferrari, M. (2008). Early and 24-hour bond strength and degree of conversion of etch-and-rinse and self-etch adhesives. AMERICAN JOURNAL OF DENTISTRY, 21(1), 30-34.

Early and 24-hour bond strength and degree of conversion of etch-and-rinse and self-etch adhesives.

FERRARI, MARCO
2008-01-01

Abstract

PURPOSE: To evaluate early and 24-hour microtensile bond strength (microTBS) and the degree of conversion (DC) of one representative adhesive system from each of the four current bonding approaches. METHODS: 40 human molars were sectioned occluso-gingivally into two halves. Resin composite was bonded incrementally to flat, mid-coronal dentin, using the adhesives Adper Scotchbond MP (MP); Adper Scotchbond 2 (SB); Clearfil SE Bond (SE); and Adper Prompt L-Pop (LP) according to the respective manufacturer's instructions (n = 10). One half was immediately sectioned into sticks and subjected to muTBS test. As the sectioning process took approximately 1 hour, the results were designated as 1-hour bond strengths. The other half was stored in distilled water at 37 degrees C for 24 hours before being sectioned and tested. The DC of these systems was measured using Fourier Transform-Raman spectroscopy in three periods: immediately, 1 and 24 hours after polymerization. Data were analyzed with ANOVA and Tukey's tests. RESULTS: There were no significant differences between the 1-hour and 24-hour bond strengths (P > 0.05), or among the DC measured immediately, 1 hour and 24 hours after polymerization (P > 0.05). However, significant differences were observed among adhesives (P < 0.05). microTBS values obtained, in MPa (1 hour/24 hour), were: SB (48.6 + 1.3/48.4 + 3.5) = SE (51.9 + 4.7/53.3 +/- 2.9) > MP (35.3 +/- 10.9/38.6 + 6.7) > LP (25.5 + 1.1/26.0 + 1.5). The DC, in percentage (immediately/1 hour/24 hour), were: SE (81/82/87) > MP (79/77/81) > SB (60/63/65) > LP (39/37/42).
2008
Sadek, F.t., Calheiros, F.c., Cardoso, P.e., Kawano, Y., Tay, F., Ferrari, M. (2008). Early and 24-hour bond strength and degree of conversion of etch-and-rinse and self-etch adhesives. AMERICAN JOURNAL OF DENTISTRY, 21(1), 30-34.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/36416
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo