Some attempts have been made in assaying glutamic-acid decarboxylase autoantibodies (GADA) in type 1 diabetic patient (T1DM) saliva. However, these salivary assays did not show sufficient sensitivity and specificity in comparison to serum assays. In this study we evaluated the ability of a fluid-phase (35)S-radioimmunoassay to detect GADA and tyrosine phosphatase 2 autoantibodies (IA-2A) in 70 T1DM, 24 T1DM first degree relatives (FDR) and 76 healthy subject saliva. Paired saliva and serum samples were collected from each subject and analyzed. GADA were detected in 45/70 (64.3%) sera and 43/70 (61.4%) T1DM saliva, respectively. IA-2A were detected in 33/70 (47.1%) sera and 30/70 (42.9%) T1DM saliva, respectively. All FDR serum/saliva samples were autoantibody negative. In conclusion, we here report that GADA and IA-2A are detectable with high sensitivity and specificity in human saliva, a specimen which can be easily collected by non-invasive procedures and may represent a reliable tool for the study of T1DM autoimmunity.
Tiberti, C., Shashaj, B., Verrienti, A., Vecci, E.G., Lucantoni, F., Masotti, D., et al. (2009). GAD and IA-2 autoantibody detection in type 1 diabetic patient saliva. CLINICAL IMMUNOLOGY, 131(2), 271-276 [10.1016/j.clim.2008.12.002].
GAD and IA-2 autoantibody detection in type 1 diabetic patient saliva
DOTTA, FRANCESCO
2009-01-01
Abstract
Some attempts have been made in assaying glutamic-acid decarboxylase autoantibodies (GADA) in type 1 diabetic patient (T1DM) saliva. However, these salivary assays did not show sufficient sensitivity and specificity in comparison to serum assays. In this study we evaluated the ability of a fluid-phase (35)S-radioimmunoassay to detect GADA and tyrosine phosphatase 2 autoantibodies (IA-2A) in 70 T1DM, 24 T1DM first degree relatives (FDR) and 76 healthy subject saliva. Paired saliva and serum samples were collected from each subject and analyzed. GADA were detected in 45/70 (64.3%) sera and 43/70 (61.4%) T1DM saliva, respectively. IA-2A were detected in 33/70 (47.1%) sera and 30/70 (42.9%) T1DM saliva, respectively. All FDR serum/saliva samples were autoantibody negative. In conclusion, we here report that GADA and IA-2A are detectable with high sensitivity and specificity in human saliva, a specimen which can be easily collected by non-invasive procedures and may represent a reliable tool for the study of T1DM autoimmunity.File | Dimensione | Formato | |
---|---|---|---|
Tiberti et al Clin Immunol 2009.pdf
non disponibili
Tipologia:
Post-print
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
234.24 kB
Formato
Adobe PDF
|
234.24 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11365/33671
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo