The impact of left ventricular (LV) diastolic dysfunction on risk of atrial fibrillation (AF) recurrence is still unknown. The aim of this study was to assess the role of LV diastolic dysfunction in predicting AF recurrence after successful electrical cardioversion in patients with nonvalvular AF. In 51 patients with a first episode of nonvalvular AF undergoing successful electrical cardioversion, tissue Doppler echocardiography was performed to measure peak early diastolic mitral annulus velocity (E(m)) and the ratio of mitral inflow to mitral annulus velocity at end-diastole (E/E(m)). Clinical end points were recurrent persistent AF at 2-week follow-up (early AF recurrence [ERAF]) and at 1-year follow-up (including ERAF and late AF recurrence). Seventeen patients showed evidence of ERAF, whereas late AF recurrence occurred in another 5 patients. In time-independent analysis E/E(m) (odds ratio [OR] 1.746, p = 0.0084) and indexed LV end-systolic volume (OR 1.083, p = 0.040) were independent predictors of ERAF. Based on a logistic model risk of ERAF was 25% for an E/E(m) of 5.6 but increased to 50% for an E/E(m) of 8.1 and to 75% for an E/E(m) of 10.5. In time-dependent analysis E/E(m) emerged as the only predictor of ERAF (OR 1.757, p = 0.0078). E/E(m) also independently predicted risk of recurrence at 1 year in time-independent (OR 1.757, p = 0.0078) and time-dependent (OR 1.319, p = 0.0003) analyses. In conclusion LV diastolic dysfunction independently predicts AF recurrence in patients with nonvalvular AF undergoing successful electrical cardioversion.

Caputo, M., Urselli, R., Capati, E., Navarri, R., Sinesi, L., Furiozzi, F., et al. (2011). Usefulness of left ventricular diastolic dysfunction assessed by pulsed tissue Doppler imaging as a predictor of atrial fibrillation recurrence after successful electrical cardioversion. THE AMERICAN JOURNAL OF CARDIOLOGY, 108(5), 698-704 [10.1016/j.amjcard.2011.04.018].

Usefulness of left ventricular diastolic dysfunction assessed by pulsed tissue Doppler imaging as a predictor of atrial fibrillation recurrence after successful electrical cardioversion.

MONDILLO, SERGIO
2011-01-01

Abstract

The impact of left ventricular (LV) diastolic dysfunction on risk of atrial fibrillation (AF) recurrence is still unknown. The aim of this study was to assess the role of LV diastolic dysfunction in predicting AF recurrence after successful electrical cardioversion in patients with nonvalvular AF. In 51 patients with a first episode of nonvalvular AF undergoing successful electrical cardioversion, tissue Doppler echocardiography was performed to measure peak early diastolic mitral annulus velocity (E(m)) and the ratio of mitral inflow to mitral annulus velocity at end-diastole (E/E(m)). Clinical end points were recurrent persistent AF at 2-week follow-up (early AF recurrence [ERAF]) and at 1-year follow-up (including ERAF and late AF recurrence). Seventeen patients showed evidence of ERAF, whereas late AF recurrence occurred in another 5 patients. In time-independent analysis E/E(m) (odds ratio [OR] 1.746, p = 0.0084) and indexed LV end-systolic volume (OR 1.083, p = 0.040) were independent predictors of ERAF. Based on a logistic model risk of ERAF was 25% for an E/E(m) of 5.6 but increased to 50% for an E/E(m) of 8.1 and to 75% for an E/E(m) of 10.5. In time-dependent analysis E/E(m) emerged as the only predictor of ERAF (OR 1.757, p = 0.0078). E/E(m) also independently predicted risk of recurrence at 1 year in time-independent (OR 1.757, p = 0.0078) and time-dependent (OR 1.319, p = 0.0003) analyses. In conclusion LV diastolic dysfunction independently predicts AF recurrence in patients with nonvalvular AF undergoing successful electrical cardioversion.
2011
Caputo, M., Urselli, R., Capati, E., Navarri, R., Sinesi, L., Furiozzi, F., et al. (2011). Usefulness of left ventricular diastolic dysfunction assessed by pulsed tissue Doppler imaging as a predictor of atrial fibrillation recurrence after successful electrical cardioversion. THE AMERICAN JOURNAL OF CARDIOLOGY, 108(5), 698-704 [10.1016/j.amjcard.2011.04.018].
File in questo prodotto:
File Dimensione Formato  
2011 Usefulness of left ventricular diastolic dysfunction.pdf

non disponibili

Tipologia: Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 400.33 kB
Formato Adobe PDF
400.33 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/32397
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo