In this paper, an innovative measurement system for odor classification, based on quartz crystal microbalances (QCMs), is presented. The application proposed in this paper is the detection of typical wine aroma compounds in mixtures containing ethanol. In QCM sensors, the sensitive layer is, e.g., a polymeric layer deposited on a quartz surface. Chemical mixtures are sorbed in the sensitive layer, inducing a change in the polymer mass and, therefore, in the quartz resonance frequency. In this paper, the frequency shift is measured by a dedicated, fully digital front-end hardware implementing a technique that allows reducing the measurement time while maintaining a high-frequency resolution . The developed system allows, therefore, measuring variations of the QCM resonance frequency shifts during chemical transients obtained with abrupt changes in odor concentration. Hence, the reaction kinetics can be exploited to enhance the sensor selectivity. In this paper, some measurements obtained with an array of four sensors with different polymeric sensitive layers are presented. An exponential fitting of the transient responses is used for feature extraction. Finally, to reduce data dimensionality, principal component analysis is used.

DI NUCCI, C., Fort, A., Rocchi, S., Tondi, L., Vignoli, V., DI FRANCESCO, F., et al. (2003). A measurement system for odor classification based on the dynamic response of QCM sensors. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 52(4), 1079-1086 [10.1109/TIM.2003.814826].

A measurement system for odor classification based on the dynamic response of QCM sensors.

FORT, ADA;ROCCHI, SANTINA;VIGNOLI, VALERIO;
2003-01-01

Abstract

In this paper, an innovative measurement system for odor classification, based on quartz crystal microbalances (QCMs), is presented. The application proposed in this paper is the detection of typical wine aroma compounds in mixtures containing ethanol. In QCM sensors, the sensitive layer is, e.g., a polymeric layer deposited on a quartz surface. Chemical mixtures are sorbed in the sensitive layer, inducing a change in the polymer mass and, therefore, in the quartz resonance frequency. In this paper, the frequency shift is measured by a dedicated, fully digital front-end hardware implementing a technique that allows reducing the measurement time while maintaining a high-frequency resolution . The developed system allows, therefore, measuring variations of the QCM resonance frequency shifts during chemical transients obtained with abrupt changes in odor concentration. Hence, the reaction kinetics can be exploited to enhance the sensor selectivity. In this paper, some measurements obtained with an array of four sensors with different polymeric sensitive layers are presented. An exponential fitting of the transient responses is used for feature extraction. Finally, to reduce data dimensionality, principal component analysis is used.
2003
DI NUCCI, C., Fort, A., Rocchi, S., Tondi, L., Vignoli, V., DI FRANCESCO, F., et al. (2003). A measurement system for odor classification based on the dynamic response of QCM sensors. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 52(4), 1079-1086 [10.1109/TIM.2003.814826].
File in questo prodotto:
File Dimensione Formato  
J16.pdf

non disponibili

Tipologia: Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 460.43 kB
Formato Adobe PDF
460.43 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/30077
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo