Interest in the pro-oxidative nature of non-protein-bound-iron (NPBI) led to the development of an assay for its detection. The aim was to set up a reliable method of detecting NPBI in small samples of biological fluids and tissue. The method was based on preferential chelation of NPBI by a large excess of the low-affinity ligand nitrilotriacetic acid. To separate NPBI, a two-step filtration procedure was used. All glassware and plasticware were treated to minimize iron contamination. Measurements were performed in plasma, amniotic fluid, bronchoalveolar lavage, and brain tissues. The analytic system detected iron as ferric nitrate standard down to a concentration of 0.01 microM. The 1,2-dimethyl-3-hydroxy-4(1H)-pyridone-Fe(DHP-Fe) complex eluted with a retention time of about 2.6 min. The standard curve for the DHP-Fe complex was linear between 0.01 and 400 microMin water as well as in plasma, bronchoalveolar lavage, brain tissue, and amniotic fluid. The detection limit was 0.01 muM for all biological fluids and brain tissue. The data show that reliable measurements of NPBI are possible in studies on oxidative stress under experimental and clinical conditions. The possibility of investigating NPBI involvement in free-radical injury might be useful in all human diseases in which oxidative stress occur.

Paffetti, P., Perrone, S., Longini, M., Ferrari, A., Tanganelli, D., Marzocchi, B., et al. (2006). Non-protein-bound iron detection in small samples of biological fluids and tissues. BIOLOGICAL TRACE ELEMENT RESEARCH, 112(3), 221-232 [10.1385/BTER:112:3:221].

Non-protein-bound iron detection in small samples of biological fluids and tissues

PAFFETTI, P.;LONGINI, M.;MARZOCCHI, B.;
2006-01-01

Abstract

Interest in the pro-oxidative nature of non-protein-bound-iron (NPBI) led to the development of an assay for its detection. The aim was to set up a reliable method of detecting NPBI in small samples of biological fluids and tissue. The method was based on preferential chelation of NPBI by a large excess of the low-affinity ligand nitrilotriacetic acid. To separate NPBI, a two-step filtration procedure was used. All glassware and plasticware were treated to minimize iron contamination. Measurements were performed in plasma, amniotic fluid, bronchoalveolar lavage, and brain tissues. The analytic system detected iron as ferric nitrate standard down to a concentration of 0.01 microM. The 1,2-dimethyl-3-hydroxy-4(1H)-pyridone-Fe(DHP-Fe) complex eluted with a retention time of about 2.6 min. The standard curve for the DHP-Fe complex was linear between 0.01 and 400 microMin water as well as in plasma, bronchoalveolar lavage, brain tissue, and amniotic fluid. The detection limit was 0.01 muM for all biological fluids and brain tissue. The data show that reliable measurements of NPBI are possible in studies on oxidative stress under experimental and clinical conditions. The possibility of investigating NPBI involvement in free-radical injury might be useful in all human diseases in which oxidative stress occur.
2006
Paffetti, P., Perrone, S., Longini, M., Ferrari, A., Tanganelli, D., Marzocchi, B., et al. (2006). Non-protein-bound iron detection in small samples of biological fluids and tissues. BIOLOGICAL TRACE ELEMENT RESEARCH, 112(3), 221-232 [10.1385/BTER:112:3:221].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/27754
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo