AIM: Several new irreversible hydrocolloid formulations have recently become available with claims of an improved dimensional stability by the manufacturers. The aim of this study was to evaluate the accuracy of casts made from alginate impression materials poured immediately and after specific storage periods. METHODS AND MATERIALS: Five alginates were tested: CA 37 (Cavex); Jeltrate (Dentsply Caulk); Jeltrate Plus (Dentsply Latin America); Hydrogum 5 (Zhermack); and Alginoplast (Heraeus Kulzer). A master model was mounted on a special device and used to obtain the impressions. These impressions were stored at 23 degrees C and 100% relative humidity, then poured with gypsum immediately, and again after 24, 72 and 120 hours. The casts were measured and the data were analyzed by one way analysis of variance (ANOVA) and Tukey test at p<0.05. RESULTS: The dimensional stability of the alginate impressions was both material and time dependent (p<0.05). After 24 hours of storage, only Alginoplast and Hydrogum 5 comply with the master model (p>0.05). After 72 and 120 hours, only Hydrogum 5 was dimensionally stable (p>0.05). CONCLUSION: The dimensional stability of the alginate impressions is influenced by the selected material and the storage time. CLINICAL SIGNIFICANCE: Alginate impressions should generally be poured immediately. However, some new types of alginate may have the pouring delayed.

Sedda, M., Casarotto, A., Raustia, A., Borracchini, A. (2008). Effect of storage time on the accuracy of casts made from different irreversible hydrocolloids. JOURNAL OF CONTEMPORARY DENTAL PRACTICE, 9(4), 1-12 [10.5005/jcdp-9-4-59].

Effect of storage time on the accuracy of casts made from different irreversible hydrocolloids

SEDDA M.;BORRACCHINI A.
2008-01-01

Abstract

AIM: Several new irreversible hydrocolloid formulations have recently become available with claims of an improved dimensional stability by the manufacturers. The aim of this study was to evaluate the accuracy of casts made from alginate impression materials poured immediately and after specific storage periods. METHODS AND MATERIALS: Five alginates were tested: CA 37 (Cavex); Jeltrate (Dentsply Caulk); Jeltrate Plus (Dentsply Latin America); Hydrogum 5 (Zhermack); and Alginoplast (Heraeus Kulzer). A master model was mounted on a special device and used to obtain the impressions. These impressions were stored at 23 degrees C and 100% relative humidity, then poured with gypsum immediately, and again after 24, 72 and 120 hours. The casts were measured and the data were analyzed by one way analysis of variance (ANOVA) and Tukey test at p<0.05. RESULTS: The dimensional stability of the alginate impressions was both material and time dependent (p<0.05). After 24 hours of storage, only Alginoplast and Hydrogum 5 comply with the master model (p>0.05). After 72 and 120 hours, only Hydrogum 5 was dimensionally stable (p>0.05). CONCLUSION: The dimensional stability of the alginate impressions is influenced by the selected material and the storage time. CLINICAL SIGNIFICANCE: Alginate impressions should generally be poured immediately. However, some new types of alginate may have the pouring delayed.
2008
Sedda, M., Casarotto, A., Raustia, A., Borracchini, A. (2008). Effect of storage time on the accuracy of casts made from different irreversible hydrocolloids. JOURNAL OF CONTEMPORARY DENTAL PRACTICE, 9(4), 1-12 [10.5005/jcdp-9-4-59].
File in questo prodotto:
File Dimensione Formato  
18473028.pdf

non disponibili

Tipologia: Abstract
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.49 MB
Formato Adobe PDF
1.49 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/26856
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo