PURPOSE: To evaluate the safety, predictability, and efficacy of sutureless synthetic keratophakia (SSK) with PermaVision intracorneal lens (Anamed) implantation. SETTING: Ophthalmic Hospital, Rome, Italy. METHODS: This retrospective study analyzed the refractive outcomes in 10 eyes of 6 patients who had SSK with PermaVision lens implantation for spherical hyperopia (cylinder less than 1.0 diopter [D]). Preoperatively, the mean spherical equivalent (SE) refraction was +4.33 D +/- 1.52 (SD) (range +3.00 to +6.37 D). All procedures were performed using the Hansatome microkeratome (Bausch & Lomb) with a superior hinge except in 1 eye in which the flap was cut using the Amadeus microkeratome (Allergan) with a nasal hinge. RESULTS: Six months after PermaVision lens insertion, the mean SE refraction was +0.03 +/- 0.36 D (range -0.50 to +0.38 D), the mean uncorrected visual acuity was 0.85 +/- 0.13 (range 0.63 to 1.00), and the mean best corrected visual acuity was 0.99 +/- 0.19 (range 0.63 to 1.25). No eye lost lines of visual acuity. In 1 eye, the lens was acutely decentered and had to be explanted. CONCLUSIONS: Sutureless synthetic keratophakia with the PermaVision intracorneal lens is a new technique for the correction of hyperopia. It is easy to perform as well as reversible, and the learning curve of the experienced laser in situ keratomileusis surgeon is short. The technique was safe and effective for spherical hyperopia, but longer follow-up and additional cases are needed to draw conclusions about the efficacy of the technique.

Michieletto, P., Ligabue, E., Balestrazzi, A., Balestrazzi, A., Giglio, S. (2004). PermaVision intracorneal lens for the correction of hyperopia. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 30(10), 2152-2157 [10.1016/j.jcrs.2004.02.093].

PermaVision intracorneal lens for the correction of hyperopia.

BALESTRAZZI, ANGELO;
2004-01-01

Abstract

PURPOSE: To evaluate the safety, predictability, and efficacy of sutureless synthetic keratophakia (SSK) with PermaVision intracorneal lens (Anamed) implantation. SETTING: Ophthalmic Hospital, Rome, Italy. METHODS: This retrospective study analyzed the refractive outcomes in 10 eyes of 6 patients who had SSK with PermaVision lens implantation for spherical hyperopia (cylinder less than 1.0 diopter [D]). Preoperatively, the mean spherical equivalent (SE) refraction was +4.33 D +/- 1.52 (SD) (range +3.00 to +6.37 D). All procedures were performed using the Hansatome microkeratome (Bausch & Lomb) with a superior hinge except in 1 eye in which the flap was cut using the Amadeus microkeratome (Allergan) with a nasal hinge. RESULTS: Six months after PermaVision lens insertion, the mean SE refraction was +0.03 +/- 0.36 D (range -0.50 to +0.38 D), the mean uncorrected visual acuity was 0.85 +/- 0.13 (range 0.63 to 1.00), and the mean best corrected visual acuity was 0.99 +/- 0.19 (range 0.63 to 1.25). No eye lost lines of visual acuity. In 1 eye, the lens was acutely decentered and had to be explanted. CONCLUSIONS: Sutureless synthetic keratophakia with the PermaVision intracorneal lens is a new technique for the correction of hyperopia. It is easy to perform as well as reversible, and the learning curve of the experienced laser in situ keratomileusis surgeon is short. The technique was safe and effective for spherical hyperopia, but longer follow-up and additional cases are needed to draw conclusions about the efficacy of the technique.
2004
Michieletto, P., Ligabue, E., Balestrazzi, A., Balestrazzi, A., Giglio, S. (2004). PermaVision intracorneal lens for the correction of hyperopia. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 30(10), 2152-2157 [10.1016/j.jcrs.2004.02.093].
File in questo prodotto:
File Dimensione Formato  
permavision-intracorneal-2004.pdf

non disponibili

Tipologia: Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 297.47 kB
Formato Adobe PDF
297.47 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/26579
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo