Objectives: to assess the effectiveness of Distal Jet without simultaneous fixed appliance treatment. Subjects and methods: twenty subjects with Class II malocclusion who received the Distal Jet appliance to move maxillary molars distally. Subsequently,the canine and premolar distal movements were achieved by the use of .017 x .025 Ni-Ti sectional wires and memory power chain. Results: revealed that Distal Jet is more effective with less anchorage loss when this appliance is used independent of multibracket appliances. Conclusion: this study showed that Distal Jet is an effective and predictable appliance. The distal movements of upper premolars, canines and incisors with sectional wires fabricated from .017 x .025 Ni-Ti were biomechanically very effective, simple in clinical application, and did not require any patient compliance.
Bolla, E., Doldo, T., Giorgetti, R. (2004). Distal movement of maxillary canines and premolars with sectional mechanics following Distal Jet application to molars [Utilizzo dei sezionali di arretramento per premolari e canini superiori dopo la distalizzazione molare con Distal Jet]. PROGRESS IN ORTHODONTICS, 5, 72-89.
Distal movement of maxillary canines and premolars with sectional mechanics following Distal Jet application to molars [Utilizzo dei sezionali di arretramento per premolari e canini superiori dopo la distalizzazione molare con Distal Jet]
Doldo T.;Giorgetti R.
2004-01-01
Abstract
Objectives: to assess the effectiveness of Distal Jet without simultaneous fixed appliance treatment. Subjects and methods: twenty subjects with Class II malocclusion who received the Distal Jet appliance to move maxillary molars distally. Subsequently,the canine and premolar distal movements were achieved by the use of .017 x .025 Ni-Ti sectional wires and memory power chain. Results: revealed that Distal Jet is more effective with less anchorage loss when this appliance is used independent of multibracket appliances. Conclusion: this study showed that Distal Jet is an effective and predictable appliance. The distal movements of upper premolars, canines and incisors with sectional wires fabricated from .017 x .025 Ni-Ti were biomechanically very effective, simple in clinical application, and did not require any patient compliance.File | Dimensione | Formato | |
---|---|---|---|
bolla progress.pdf
non disponibili
Tipologia:
Post-print
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
224.03 kB
Formato
Adobe PDF
|
224.03 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11365/25824
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo