Application of fMRI to clinical neurology implies the selection of a simple task and control of the task performance. The capability to objectively monitor variables related to task execution is, therefore, important and could improve accuracy of clinical fMRI studies. We assessed the influence of different self-paced frequencies of a simple motor task on brain activation in healthy subjects. A device was developed to measure the force exerted by a subject in pressing an air-filled rubber bulb with the last four fingers of the dominant hand. The task frequency was determined by analysis of the force signal. Nine healthy subjects performed twice the task with self-paced slow (0.35+/-0.09 Hz), intermediate (0.58+/-0.21 Hz) or fast (0.98+/-0.32 Hz) frequency. The device revealed impaired task execution in 1 subject. The coefficient of variation of frequency was 8.7% for slow, 12.2% for intermediate and 15.8% for fast paced task. No significant differences were found comparing the activation maps obtained at slow, intermediate and fast frequencies in the contralateral sensorimotor cortex and ipsilateral cerebellum. Cluster reproducibility was good for location (standard deviation<or=7.3 mm), but poor for signal intensity (coefficient of variation 0-176.8%) and extent (coefficient of variation 1.9-140.6%). In conclusion, self-paced frequency variations of a simple motor task in the 0.2-2 Hz range are not a relevant source of the variability of the fMRI results in healthy subjects. Use of the device for evaluation of the neurologically impaired patients might broaden the clinical applications of fMRI.

Diciotti, S., Gavazzi, C., DELLA NAVE, R., Boni, E., Ginestroni, A., Paoli, L., et al. (2007). Self-paced frequency of a simple motor task and brain activation. A fMRI study in healthy subjects using an on-line monitor device. NEUROIMAGE, 38(3), 402-412 [10.1016/j.neuroimage.2007.07.045].

Self-paced frequency of a simple motor task and brain activation. A fMRI study in healthy subjects using an on-line monitor device.

DE STEFANO, NICOLA;
2007-01-01

Abstract

Application of fMRI to clinical neurology implies the selection of a simple task and control of the task performance. The capability to objectively monitor variables related to task execution is, therefore, important and could improve accuracy of clinical fMRI studies. We assessed the influence of different self-paced frequencies of a simple motor task on brain activation in healthy subjects. A device was developed to measure the force exerted by a subject in pressing an air-filled rubber bulb with the last four fingers of the dominant hand. The task frequency was determined by analysis of the force signal. Nine healthy subjects performed twice the task with self-paced slow (0.35+/-0.09 Hz), intermediate (0.58+/-0.21 Hz) or fast (0.98+/-0.32 Hz) frequency. The device revealed impaired task execution in 1 subject. The coefficient of variation of frequency was 8.7% for slow, 12.2% for intermediate and 15.8% for fast paced task. No significant differences were found comparing the activation maps obtained at slow, intermediate and fast frequencies in the contralateral sensorimotor cortex and ipsilateral cerebellum. Cluster reproducibility was good for location (standard deviation
2007
Diciotti, S., Gavazzi, C., DELLA NAVE, R., Boni, E., Ginestroni, A., Paoli, L., et al. (2007). Self-paced frequency of a simple motor task and brain activation. A fMRI study in healthy subjects using an on-line monitor device. NEUROIMAGE, 38(3), 402-412 [10.1016/j.neuroimage.2007.07.045].
File in questo prodotto:
File Dimensione Formato  
122.pdf

non disponibili

Tipologia: Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.34 MB
Formato Adobe PDF
1.34 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/22663
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo