We present encouraging results obtained with an experimental apparatus based on coherent population trapping and aimed at detecting a biological (cardiac) magnetic field in a magnetically compensated but unshielded volume. The work includes magnetic-field and magnetic-field-gradient compensation and uses differential detection to cancel common mode magnetic noise. Synchronous data acquisition with a reference (electrocardiographic or pulse-oximetric) signal makes possible improvement of the signal-to-noise ratio in off-line averaging. The setup has the significant advantages of working at room temperature with a small-size head, and the possibility of fast adjustments of the dc bias magnetic field, which makes the sensor suitable for detecting a biomagnetic signal at any orientation with respect to the axis of the head and in any position on the patient’s chest, which is not the case with other kinds of magnetometers.
Belfi, J., Bevilacqua, G., Biancalana, V., Cartaleva, S., Dancheva, Y., Moi, L. (2007). Cesium coherent population trapping magnetometer for cardiosignal detection in an unshielded environment. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. B, OPTICAL PHYSICS, 24(9), 2357-2362 [10.1364/JOSAB.24.002357].
Cesium coherent population trapping magnetometer for cardiosignal detection in an unshielded environment
BELFI, JACOPO;BEVILACQUA, GIUSEPPE;BIANCALANA, VALERIO;DANCHEVA, YORDANKA;MOI, LUIGI
2007-01-01
Abstract
We present encouraging results obtained with an experimental apparatus based on coherent population trapping and aimed at detecting a biological (cardiac) magnetic field in a magnetically compensated but unshielded volume. The work includes magnetic-field and magnetic-field-gradient compensation and uses differential detection to cancel common mode magnetic noise. Synchronous data acquisition with a reference (electrocardiographic or pulse-oximetric) signal makes possible improvement of the signal-to-noise ratio in off-line averaging. The setup has the significant advantages of working at room temperature with a small-size head, and the possibility of fast adjustments of the dc bias magnetic field, which makes the sensor suitable for detecting a biomagnetic signal at any orientation with respect to the axis of the head and in any position on the patient’s chest, which is not the case with other kinds of magnetometers.File | Dimensione | Formato | |
---|---|---|---|
magneto cardio josa published.pdf
non disponibili
Tipologia:
Post-print
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
302.11 kB
Formato
Adobe PDF
|
302.11 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11365/21599
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo