A zymogram method for detecting elastase activity following isoelectric focusing in polyacrylamide gel is described. After enzyme activity has been visualized, the gel itself is available for protein staining and for analysis in sodium dodecyl sulfate-polyacrylamide gel electrophoresis in second dimension. The zymogram method is suitable for detecting microgram amounts of elastase and has one step only. It can be used with the purified enzyme as well as with crude extracts of tissue containing elastases showing activity toward succinyl-(Ala)3-p-nitroanilide. By this method a major component of elastase in both porcine and rat pancreas was detected. In addition, two forms of elastase with isoelectric points of 8.2 and 8.8, respectively, were identified in rat leukocyte extracts.

Gardi, C., Lungarella, G. (1984). Detection of elastase activity with a zymogram method after isoelectric focusing in polyacrylamide gel. ANALYTICAL BIOCHEMISTRY, 140(2), 472-477 [10.1016/0003-2697(84)90196-9].

Detection of elastase activity with a zymogram method after isoelectric focusing in polyacrylamide gel

Gardi, C.;Lungarella, G.
1984-01-01

Abstract

A zymogram method for detecting elastase activity following isoelectric focusing in polyacrylamide gel is described. After enzyme activity has been visualized, the gel itself is available for protein staining and for analysis in sodium dodecyl sulfate-polyacrylamide gel electrophoresis in second dimension. The zymogram method is suitable for detecting microgram amounts of elastase and has one step only. It can be used with the purified enzyme as well as with crude extracts of tissue containing elastases showing activity toward succinyl-(Ala)3-p-nitroanilide. By this method a major component of elastase in both porcine and rat pancreas was detected. In addition, two forms of elastase with isoelectric points of 8.2 and 8.8, respectively, were identified in rat leukocyte extracts.
1984
Gardi, C., Lungarella, G. (1984). Detection of elastase activity with a zymogram method after isoelectric focusing in polyacrylamide gel. ANALYTICAL BIOCHEMISTRY, 140(2), 472-477 [10.1016/0003-2697(84)90196-9].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/21456
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo