Two chromatographic methods were developed for the determination of erythromycin A (EA) residues in animal tissues (muscle, liver, kidney and fat of cattle, pigs and poultry) and cow's milk. In addition to a more traditional method using electrochemical detection, we developed an original alternative method based on UV detection at 236 nm, by pretreating to create a chromophore in the molecule. An internal standard was used with both methods to check the variability of the analytical system. Analysis times and performance were compared. The recovery of EA from various matrices was greater than 95%. For both methods the quantification limit for EA was 0.25 μg ml-1 for plasma, 0.025 μg g-1 for milk and 0.125 μg g-1 for the other biological matrices. The methods can be used to check for EA residues in these matrices; in fact, the statutory maximum residue limits (MRLs) of EA are 0.4 μg g-1 in muscle, kidney, liver and fat of beef cattle, sheep, pigs and poultry, and 0.04 μg g-1 in cow's and sheep's milk.

Dreassi, E., Corti, P., Bezzini, F., Furlanetto, S. (2000). High-performance liquid chromatographic assayof erythromycin from biological matrix using electrochemical or ultraviolet detection. ANALYST, 125(6), 1077-1081 [10.1039/a909876c].

High-performance liquid chromatographic assayof erythromycin from biological matrix using electrochemical or ultraviolet detection

DREASSI E.;CORTI P.;
2000-01-01

Abstract

Two chromatographic methods were developed for the determination of erythromycin A (EA) residues in animal tissues (muscle, liver, kidney and fat of cattle, pigs and poultry) and cow's milk. In addition to a more traditional method using electrochemical detection, we developed an original alternative method based on UV detection at 236 nm, by pretreating to create a chromophore in the molecule. An internal standard was used with both methods to check the variability of the analytical system. Analysis times and performance were compared. The recovery of EA from various matrices was greater than 95%. For both methods the quantification limit for EA was 0.25 μg ml-1 for plasma, 0.025 μg g-1 for milk and 0.125 μg g-1 for the other biological matrices. The methods can be used to check for EA residues in these matrices; in fact, the statutory maximum residue limits (MRLs) of EA are 0.4 μg g-1 in muscle, kidney, liver and fat of beef cattle, sheep, pigs and poultry, and 0.04 μg g-1 in cow's and sheep's milk.
2000
Dreassi, E., Corti, P., Bezzini, F., Furlanetto, S. (2000). High-performance liquid chromatographic assayof erythromycin from biological matrix using electrochemical or ultraviolet detection. ANALYST, 125(6), 1077-1081 [10.1039/a909876c].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/20694
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo