Purpose: To assess the degree of conversion (DC) at different levels of a resin-based luting agent used with different commercial posts. Methods: A resin-based luting agent (Variolink II) was light-cured in a simulated dowel space in combination with different fiber posts: GC Fiber Post (GC), DT Light Safety Lock (SL), RelyX Fiber Post (RX), Reforpost (RE), DT Light Post Illusion (LPI), FRC Postec Plus (FP), Radix (RA), Snowpost (SP), Dentin Post X (DP), Macro lock Illusion (MI), and Composipost (CP). After 24 hours, DC was assessed through micro-Raman analysis at the coronal, middle, and apical thirds. Two-way ANOVA and Tukey test were used for post-hoc comparisons (P< 0.05). Results: The results demonstrated that the post-type, dowel space level, and between-factor interaction were statistically significant (P< 0.001). Differences in DC were observed at different depths for RX, RE, LPI, SL, DP, MI and CP, decreasing from the coronal to the apical third. Although the resin-based luting agent should be able to polymerize in absence of light, a higher DC was found following light irradiation (with a decreasing effect from the coronal to the apical third). (Am J Dent 2012;25:17-20).

Navarra, C.O., Goracci, C., Breschi, L., Vichi, A., Corciolani, G., Cadenaro, M., et al. (2012). Influence of post type on degree of conversion of a resin-based luting agent. AMERICAN JOURNAL OF DENTISTRY, 25(1), 17-20.

Influence of post type on degree of conversion of a resin-based luting agent

Goracci C.;Vichi A.;Ferrari M.
2012-01-01

Abstract

Purpose: To assess the degree of conversion (DC) at different levels of a resin-based luting agent used with different commercial posts. Methods: A resin-based luting agent (Variolink II) was light-cured in a simulated dowel space in combination with different fiber posts: GC Fiber Post (GC), DT Light Safety Lock (SL), RelyX Fiber Post (RX), Reforpost (RE), DT Light Post Illusion (LPI), FRC Postec Plus (FP), Radix (RA), Snowpost (SP), Dentin Post X (DP), Macro lock Illusion (MI), and Composipost (CP). After 24 hours, DC was assessed through micro-Raman analysis at the coronal, middle, and apical thirds. Two-way ANOVA and Tukey test were used for post-hoc comparisons (P< 0.05). Results: The results demonstrated that the post-type, dowel space level, and between-factor interaction were statistically significant (P< 0.001). Differences in DC were observed at different depths for RX, RE, LPI, SL, DP, MI and CP, decreasing from the coronal to the apical third. Although the resin-based luting agent should be able to polymerize in absence of light, a higher DC was found following light irradiation (with a decreasing effect from the coronal to the apical third). (Am J Dent 2012;25:17-20).
2012
Navarra, C.O., Goracci, C., Breschi, L., Vichi, A., Corciolani, G., Cadenaro, M., et al. (2012). Influence of post type on degree of conversion of a resin-based luting agent. AMERICAN JOURNAL OF DENTISTRY, 25(1), 17-20.
File in questo prodotto:
File Dimensione Formato  
2012a Am J Dent. Influence of post type on degree of conversion of a resin-based luting agent.pdf

non disponibili

Tipologia: Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 262.82 kB
Formato Adobe PDF
262.82 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/20372
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo