Targeted Radionuclide Therapy (TRT) is a well-established technique for cancer treatment. In this approach, radionuclides are bound to specific drugs that selectively transport them to the tumor site. Within the ISOLPHARM project, a radiopharmaceutical for TRT based on the innovative radionuclide 111Ag is currently under development. 111Ag has a half-life of 7.45 days and decays by emitting both electrons and gamma-rays. The emission of gamma-rays, predominantly at an energy of 342 keV, enables the visualization of 111Ag using a gamma camera. In this work, we describe a Monte Carlo simulation developed to optimize the design parameters of such an imaging device. The simulation is based on the Geant4 toolkit, which accurately models the interactions between particles and matter. The estimated spatial resolution and sensitivity of the system are approximately 4 mm and 19 cps/MBq, respectively. The simulated device is able to resolve lesions with a lesion-to-background activity ratio of 4:1 under in-vivo-like conditions. These results indicate that the proposed gamma camera can provide cost-effective imaging capabilities for preclinical radiopharmaceutical studies.

Serafini, D., Leso, A., Arzenton, A., Spadano, S., Borciani, E., Chen, D., et al. (2026). Monte Carlo simulation of the ISOLPHARM gamma camera for Ag-111 imaging. JOURNAL OF INSTRUMENTATION, 21(04) [10.1088/1748-0221/21/04/c04037].

Monte Carlo simulation of the ISOLPHARM gamma camera for Ag-111 imaging

Serafini, D.
;
Arzenton, A.;Mariotti, E.;
2026-01-01

Abstract

Targeted Radionuclide Therapy (TRT) is a well-established technique for cancer treatment. In this approach, radionuclides are bound to specific drugs that selectively transport them to the tumor site. Within the ISOLPHARM project, a radiopharmaceutical for TRT based on the innovative radionuclide 111Ag is currently under development. 111Ag has a half-life of 7.45 days and decays by emitting both electrons and gamma-rays. The emission of gamma-rays, predominantly at an energy of 342 keV, enables the visualization of 111Ag using a gamma camera. In this work, we describe a Monte Carlo simulation developed to optimize the design parameters of such an imaging device. The simulation is based on the Geant4 toolkit, which accurately models the interactions between particles and matter. The estimated spatial resolution and sensitivity of the system are approximately 4 mm and 19 cps/MBq, respectively. The simulated device is able to resolve lesions with a lesion-to-background activity ratio of 4:1 under in-vivo-like conditions. These results indicate that the proposed gamma camera can provide cost-effective imaging capabilities for preclinical radiopharmaceutical studies.
2026
Serafini, D., Leso, A., Arzenton, A., Spadano, S., Borciani, E., Chen, D., et al. (2026). Monte Carlo simulation of the ISOLPHARM gamma camera for Ag-111 imaging. JOURNAL OF INSTRUMENTATION, 21(04) [10.1088/1748-0221/21/04/c04037].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/1314014
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo