This study presents a new concept related to the quality and usability of multispectral (MS) and panchromatic (PAN) data sets captured by very-/extremely high-resolution (VHR/EHR) satellite MS scanners. Despite the ever-increasing resolution and spectral coverage capabilities of modern instruments, MS datasets suffer from the presence of aliasing originating from the insufficient sampling step size, corresponding to a high value of the modulation transfer function (MTF) of the instrument at the Nyquist frequency. Another source of degradation is the local misalignment between interpolated MS and PAN, originating from different viewpoints along the orbit of the instruments in the presence of discontinuities of the imaged surface. Here, we propose a procedure to harmonize MS and PAN datasets: aliasing artifacts of MS are suppressed; local MS-to-MS and MS-to-PAN shifts are damped. This is feasible for the unimodality of the MS and PAN instruments. Harmonization of MS towards PAN is achieved by injecting the least squares (LS) residue of the multivariate linear regression of the interpolated bands captured by each MS scanner towards the lowpass-filtered PAN. Experiments with two (MS-PAN) and three (MS1-MS2-PAN) on-board instruments show that an almost perfect alignment and a significant reduction of aliasing patterns are achieved. MS pansharpening greatly benefits from harmonized datasets. When the latter are used for the fusion and as references of spectral and spatial qualities of fusion products, inconsistencies noticed and complained about in the literature vanish. The procedure is in real time, fully automated, and does not require additional or ancillary information.

Alparone, L., Arienzo, A., Garzelli, A. (2025). Harmonization of Multispectral and Panchromatic Images From VHR/EHR Spaceborne Scanners. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 63, 1-16 [10.1109/tgrs.2025.3605739].

Harmonization of Multispectral and Panchromatic Images From VHR/EHR Spaceborne Scanners

Garzelli, Andrea
2025-01-01

Abstract

This study presents a new concept related to the quality and usability of multispectral (MS) and panchromatic (PAN) data sets captured by very-/extremely high-resolution (VHR/EHR) satellite MS scanners. Despite the ever-increasing resolution and spectral coverage capabilities of modern instruments, MS datasets suffer from the presence of aliasing originating from the insufficient sampling step size, corresponding to a high value of the modulation transfer function (MTF) of the instrument at the Nyquist frequency. Another source of degradation is the local misalignment between interpolated MS and PAN, originating from different viewpoints along the orbit of the instruments in the presence of discontinuities of the imaged surface. Here, we propose a procedure to harmonize MS and PAN datasets: aliasing artifacts of MS are suppressed; local MS-to-MS and MS-to-PAN shifts are damped. This is feasible for the unimodality of the MS and PAN instruments. Harmonization of MS towards PAN is achieved by injecting the least squares (LS) residue of the multivariate linear regression of the interpolated bands captured by each MS scanner towards the lowpass-filtered PAN. Experiments with two (MS-PAN) and three (MS1-MS2-PAN) on-board instruments show that an almost perfect alignment and a significant reduction of aliasing patterns are achieved. MS pansharpening greatly benefits from harmonized datasets. When the latter are used for the fusion and as references of spectral and spatial qualities of fusion products, inconsistencies noticed and complained about in the literature vanish. The procedure is in real time, fully automated, and does not require additional or ancillary information.
2025
Alparone, L., Arienzo, A., Garzelli, A. (2025). Harmonization of Multispectral and Panchromatic Images From VHR/EHR Spaceborne Scanners. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 63, 1-16 [10.1109/tgrs.2025.3605739].
File in questo prodotto:
File Dimensione Formato  
Harmonization_of_Multispectral_and_Panchromatic_Images_From_VHR_EHR_Spaceborne_Scanners.pdf

non disponibili

Tipologia: PDF editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 8.63 MB
Formato Adobe PDF
8.63 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/1299855