Steam pop (SP) refers to audible sound related to the intramyocardial explosion when tissue temperatures reach 100 °C. In this case the SP was recorded using intracardiac echocardiography (ICE), using Sound-star probe and Smart-touch catheter with ablation index (AI) module (Biosense-Webster Inc., Diamond-Bar, CA, USA). Guided by the anatomical reconstruction (EAM) and electrograms, we applied radiofrequencies (RF) in a “point-by-point” along the entire line on cavo-tricuspid-isthmus (CTI) using a target of an AI ≥500. The tip-tissue force recorded was 12–18 g and a power of 35 W. ICE imaging was important so that the anatomical position of the catheter tip can be precisely monitored. During RF, ICE showed a growing, hyperechogenic intramyocardial bubble at the catheter-tissue interface. ICE imaging showed a hyperechogenic intramyocardial formation at the moment of occurrence of the SP. ICE imaging showed that the formation suddenly expanded to a sphere over the course of several seconds. After SP we reduced the RF output energy from 35 W to 30 W. After RF line on CTI the patient had no complications and no recurrence of atrial flutter was recorded. [removed] © 2020 Japanese College of Cardiology
Santoro, A., Romano, A., Lamberti, F. (2021). Steam pop during cavo-tricuspid isthmus ablation shown by intracardiac echocardiography. JOURNAL OF CARDIOLOGY CASES, 23(1), 13-15 [10.1016/j.jccase.2020.08.002].
Steam pop during cavo-tricuspid isthmus ablation shown by intracardiac echocardiography
Santoro A;
2021-01-01
Abstract
Steam pop (SP) refers to audible sound related to the intramyocardial explosion when tissue temperatures reach 100 °C. In this case the SP was recorded using intracardiac echocardiography (ICE), using Sound-star probe and Smart-touch catheter with ablation index (AI) module (Biosense-Webster Inc., Diamond-Bar, CA, USA). Guided by the anatomical reconstruction (EAM) and electrograms, we applied radiofrequencies (RF) in a “point-by-point” along the entire line on cavo-tricuspid-isthmus (CTI) using a target of an AI ≥500. The tip-tissue force recorded was 12–18 g and a power of 35 W. ICE imaging was important so that the anatomical position of the catheter tip can be precisely monitored. During RF, ICE showed a growing, hyperechogenic intramyocardial bubble at the catheter-tissue interface. ICE imaging showed a hyperechogenic intramyocardial formation at the moment of occurrence of the SP. ICE imaging showed that the formation suddenly expanded to a sphere over the course of several seconds. After SP we reduced the RF output energy from 35 W to 30 W. After RF line on CTI the patient had no complications and no recurrence of atrial flutter was recorded. [removed] © 2020 Japanese College of Cardiology| File | Dimensione | Formato | |
|---|---|---|---|
|
steam pop pubb.pdf
non disponibili
Descrizione: Free full-text sul sito dell'editore e su PMC
Tipologia:
PDF editoriale
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
537.53 kB
Formato
Adobe PDF
|
537.53 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11365/1295220