Objective The advent of new technologies and the discovery of new antigenic targets of autoantibodies has led to significant changes in autoimmune diagnostics worldwide. To address the extent to which autoimmunology laboratories adhere to such innovation in testing and reporting practices, the Italian Society of Clinical Pathology and Laboratory Medicine launched a national survey to assess the current status of autoimmune diagnostics and to provide direction for further harmonisation. Methods A questionnaire covering topics related to the diagnosis of autoimmune systemic rheumatic diseases was distributed to 152 Italian autoimmunology laboratories. The 59 closed-answer questions were subdivided into four main sections: 1. the setting (university, hospital or private laboratory) and the number of tests carried out; 2. the technologies used and their level of automation; 3. the analytical phase (antibody tests and methods), including awareness of the International Consensus on ANA Patterns (ICAP) initiative; 4. reporting of results and clinician relations. Results A total of 121 laboratories (79.6%) responded to the survey (15% universities, 70 hospitals, and 15% private laboratories). Indirect immunofluorescence is used by 94.8% of respondents, chemiluminescence by 78.4%, fluoro-immuno-enzymatic assays by 67.5%, immunodot by 52.6%, line-immunoassay by 47.4%, addressable laser bead immunoassay by 10.3% and radioimmunological methods by 10.2%. The great majority of respondents implemented complete automation of the listed methodologies. 65% of participants state that they add an interpretative comment in the report. 45% of participants enjoy a collaborative relationship with clinicians; counselling activities are provided by almost half of participants. Conclusion Survey results indicated that almost all respondent laboratories have broadened their antibody panel and that high-throughput technologies have been widely introduced. Gaps identified by the survey include a still incomplete compliance with guidelines in antibody profiles (e.g. in antiphospholipid syndrome and rheumatoid arthritis and reporting of test results. Awareness of these differences provides insights that may further contribute to achieving harmonisation in autoimmune diagnostics.
Carbone, T., Infantino, M., Antico, A., Porcelli, B., Villalta, D., Pafundi, V., et al. (2023). An Italian nationwide survey on the evolution of autoantibody diagnostics in autoimmune rheumatic diseases. CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 41(11), 2277-2285 [10.55563/clinexprheumatol/bhnk4l].
An Italian nationwide survey on the evolution of autoantibody diagnostics in autoimmune rheumatic diseases
Porcelli, Brunetta;
2023-01-01
Abstract
Objective The advent of new technologies and the discovery of new antigenic targets of autoantibodies has led to significant changes in autoimmune diagnostics worldwide. To address the extent to which autoimmunology laboratories adhere to such innovation in testing and reporting practices, the Italian Society of Clinical Pathology and Laboratory Medicine launched a national survey to assess the current status of autoimmune diagnostics and to provide direction for further harmonisation. Methods A questionnaire covering topics related to the diagnosis of autoimmune systemic rheumatic diseases was distributed to 152 Italian autoimmunology laboratories. The 59 closed-answer questions were subdivided into four main sections: 1. the setting (university, hospital or private laboratory) and the number of tests carried out; 2. the technologies used and their level of automation; 3. the analytical phase (antibody tests and methods), including awareness of the International Consensus on ANA Patterns (ICAP) initiative; 4. reporting of results and clinician relations. Results A total of 121 laboratories (79.6%) responded to the survey (15% universities, 70 hospitals, and 15% private laboratories). Indirect immunofluorescence is used by 94.8% of respondents, chemiluminescence by 78.4%, fluoro-immuno-enzymatic assays by 67.5%, immunodot by 52.6%, line-immunoassay by 47.4%, addressable laser bead immunoassay by 10.3% and radioimmunological methods by 10.2%. The great majority of respondents implemented complete automation of the listed methodologies. 65% of participants state that they add an interpretative comment in the report. 45% of participants enjoy a collaborative relationship with clinicians; counselling activities are provided by almost half of participants. Conclusion Survey results indicated that almost all respondent laboratories have broadened their antibody panel and that high-throughput technologies have been widely introduced. Gaps identified by the survey include a still incomplete compliance with guidelines in antibody profiles (e.g. in antiphospholipid syndrome and rheumatoid arthritis and reporting of test results. Awareness of these differences provides insights that may further contribute to achieving harmonisation in autoimmune diagnostics.File | Dimensione | Formato | |
---|---|---|---|
An Italian nationwide survey on the evolution of autoantibody diagnostics in autoimmune rheumatic diseases.pdf
non disponibili
Descrizione: articolo
Tipologia:
PDF editoriale
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
4.34 MB
Formato
Adobe PDF
|
4.34 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11365/1280812