Redox imbalance and oxidative stress-related biomarkers are raising increasing consensus in the scientific community for their significant role in a wide range of human disorders. In this framework, the total antioxidant capacity (TAC), namely, the overall pattern of both enzymatic and nonenzymatic antioxidant compounds within the body, represents an important bioanalytical parameter. To date, however, antioxidant assays require costly instrumentations, laboratory setups, and reagents, and they are invasive. Yet, their accuracy typically suffers from strong sensitivity to interfering matrices and inability to detect the complete pattern of physiological antioxidant molecules, due to the use of reaction schemes and probes/substrates that are not sensitive to the diverse range of relevant target species. Here, we exploit the enzyme-mimetic properties of platinum nanoparticles combined with hydroxyl radical probes produced at the particle surface to develop an effective detection scheme that is sensitive to both single electron transfer (SET) and hydrogen atom transfer (HAT) reactions, thus covering all the physiologically relevant antioxidant species. Importantly, the nanozyme-enabled method allows fast (5 min), accurate, and noninvasive evaluation of the body TAC through saliva via simple naked-eye or smartphone-based inspection.

Pedone, D., Moglianetti, M., Lettieri, M., Marrazza, G., Pompa, P.P. (2020). Platinum Nanozyme-Enabled Colorimetric Determination of Total Antioxidant Level in Saliva. ANALYTICAL CHEMISTRY, 92(13), 8660-8664 [10.1021/acs.analchem.0c01824].

Platinum Nanozyme-Enabled Colorimetric Determination of Total Antioxidant Level in Saliva

Lettieri M.;
2020-01-01

Abstract

Redox imbalance and oxidative stress-related biomarkers are raising increasing consensus in the scientific community for their significant role in a wide range of human disorders. In this framework, the total antioxidant capacity (TAC), namely, the overall pattern of both enzymatic and nonenzymatic antioxidant compounds within the body, represents an important bioanalytical parameter. To date, however, antioxidant assays require costly instrumentations, laboratory setups, and reagents, and they are invasive. Yet, their accuracy typically suffers from strong sensitivity to interfering matrices and inability to detect the complete pattern of physiological antioxidant molecules, due to the use of reaction schemes and probes/substrates that are not sensitive to the diverse range of relevant target species. Here, we exploit the enzyme-mimetic properties of platinum nanoparticles combined with hydroxyl radical probes produced at the particle surface to develop an effective detection scheme that is sensitive to both single electron transfer (SET) and hydrogen atom transfer (HAT) reactions, thus covering all the physiologically relevant antioxidant species. Importantly, the nanozyme-enabled method allows fast (5 min), accurate, and noninvasive evaluation of the body TAC through saliva via simple naked-eye or smartphone-based inspection.
2020
Pedone, D., Moglianetti, M., Lettieri, M., Marrazza, G., Pompa, P.P. (2020). Platinum Nanozyme-Enabled Colorimetric Determination of Total Antioxidant Level in Saliva. ANALYTICAL CHEMISTRY, 92(13), 8660-8664 [10.1021/acs.analchem.0c01824].
File in questo prodotto:
File Dimensione Formato  
Pedone, Moglianetti, Lettieri et al., 2020.pdf

accesso aperto

Tipologia: Post-print
Licenza: PUBBLICO - Pubblico con Copyright
Dimensione 1.68 MB
Formato Adobe PDF
1.68 MB Adobe PDF Visualizza/Apri
Platinum Nanozyme-Enabled Colorimetric Determination of Total Antioxidant Level in Saliva.pdf

non disponibili

Descrizione: free full text sul sito dell'editore
Tipologia: PDF editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.88 MB
Formato Adobe PDF
1.88 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/1278579