Background: This study aims to compare three commonly used energy devices for dissection during Video-Assisted Thoracoscopic Surgery (VATS) lobectomy: monopolar hook, advanced bipolar, and ultrasonic device, in terms of duration of the surgical procedure and clinical intra- and post-operative outcomes. Materials and methods: In this prospective single-center study, 75 patients undergoing VATS lobectomy for non-small cell lung cancer between January 2022 and May 2023 were enrolled and divided into 3 groups based on the device used during the surgical procedure (Group 1: Ultrasonic Device, Group 2: Advanced Bipolar, Group 3: Monopolar Hook). The duration of the surgical procedure, daily pleural fluid production, post-operative pain, length of hospital stay, and occurrence of post-operative complications were compared for each group. In a subgroup of 20 patients (10 from Group 1 and 10 from Group 3), concentrations of inflammatory cytokines in pleural fluid at 3 h and 48 h post-surgery were analyzed. Results: Pleural fluid production on the first and second post-operative days was significantly lower in patients treated with the Ultrasonic device compared to the other two groups (p < 0.001). The duration of the surgical procedure was significantly shorter when using the Ultrasonic device (p < 0.001). There were no significant differences in length of hospital stay (p = 0.975), pain on the first and second post-operative days (p = 0.147 and p = 0.755, respectively), and blood hemoglobin levels on the first post-operative day (p = 0.709) and at discharge (p = 0.795). No differences were observed in terms of post-operative complications, although the incidence of post-operative cardiac arrhythmias was borderline significant (p = 0.096), with no cases of arrhythmias recorded in Group 1. IL-10 levels in pleural fluid of patients in Group 3 peaked at 3 h post-surgery, with a significant reduction at 48 h (p = 0.459). Discussion: The use of the ultrasonic device during VATS lobectomy may reduce pleural fluid production and shorten the duration of the surgical procedure compared to using a monopolar hook or advanced bipolar device. The choice of energy device may influence the local inflammatory response, although further studies are needed to confirm these results.
Catelli, C., D'Alessandro, M., Mathieu, F., Addamo, E., Franchi, F., Paladini, P., et al. (2024). Clinical and biological effects of different energetic surgical devices currently used for mini-invasive anatomical lung resections for the treatment of NSCLC: a prospective interventional study. SURGICAL ENDOSCOPY, 38(8), 4753-4761 [10.1007/s00464-024-11014-3].
Clinical and biological effects of different energetic surgical devices currently used for mini-invasive anatomical lung resections for the treatment of NSCLC: a prospective interventional study
Catelli C.
Conceptualization
;D'Alessandro M.Data Curation
;Mathieu F.Software
;Addamo E.Investigation
;Franchi F.Supervision
;Paladini P.Project Administration
;Luzzi L.Conceptualization
2024-01-01
Abstract
Background: This study aims to compare three commonly used energy devices for dissection during Video-Assisted Thoracoscopic Surgery (VATS) lobectomy: monopolar hook, advanced bipolar, and ultrasonic device, in terms of duration of the surgical procedure and clinical intra- and post-operative outcomes. Materials and methods: In this prospective single-center study, 75 patients undergoing VATS lobectomy for non-small cell lung cancer between January 2022 and May 2023 were enrolled and divided into 3 groups based on the device used during the surgical procedure (Group 1: Ultrasonic Device, Group 2: Advanced Bipolar, Group 3: Monopolar Hook). The duration of the surgical procedure, daily pleural fluid production, post-operative pain, length of hospital stay, and occurrence of post-operative complications were compared for each group. In a subgroup of 20 patients (10 from Group 1 and 10 from Group 3), concentrations of inflammatory cytokines in pleural fluid at 3 h and 48 h post-surgery were analyzed. Results: Pleural fluid production on the first and second post-operative days was significantly lower in patients treated with the Ultrasonic device compared to the other two groups (p < 0.001). The duration of the surgical procedure was significantly shorter when using the Ultrasonic device (p < 0.001). There were no significant differences in length of hospital stay (p = 0.975), pain on the first and second post-operative days (p = 0.147 and p = 0.755, respectively), and blood hemoglobin levels on the first post-operative day (p = 0.709) and at discharge (p = 0.795). No differences were observed in terms of post-operative complications, although the incidence of post-operative cardiac arrhythmias was borderline significant (p = 0.096), with no cases of arrhythmias recorded in Group 1. IL-10 levels in pleural fluid of patients in Group 3 peaked at 3 h post-surgery, with a significant reduction at 48 h (p = 0.459). Discussion: The use of the ultrasonic device during VATS lobectomy may reduce pleural fluid production and shorten the duration of the surgical procedure compared to using a monopolar hook or advanced bipolar device. The choice of energy device may influence the local inflammatory response, although further studies are needed to confirm these results.File | Dimensione | Formato | |
---|---|---|---|
s00464-024-11014-3 (1).pdf
non disponibili
Descrizione: Articolo
Tipologia:
PDF editoriale
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
1.11 MB
Formato
Adobe PDF
|
1.11 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11365/1277326