Purpose: Concurrently with the growing interest in CAD-CAM systems, several new materials of different chemical nature have become available. As an alternative to ceramics, numerous polymer-based materials have recently been proposed for permanent prosthetic restorations. Aim of this study was to test the CAD-CAM polymer-based materials available on the market, comparing mean flexural strength, Weibull characteristic strength and Weibull modulus. Methods: Seven types of polymer-based blocks were tested: Lava Ultimate, 3M; Brilliant Crios, Coltene; Cerasmart, GC; Block HC, Shofu; Katana Avencia, Noritake; Grandio Blocs, Voco; Tetric CAD, and Ivoclar-Vivadent. Specimens were cut out from blocks, finished, polished, and tested in a three-point bending test apparatus until failure (n=30). Flexural strength, Weibull characteristic strength, and Weibull modulus were calculated. Flexural strength data were statistically analyzed. ANOVA on Ranks was applied, followed by the Dunn's test for post hoc comparisons (P= 0.05). Results: Flexural strength values (MPa) were measured (mean±standard deviation). Different letters in parentheses label statistically significant differences: Grandio Blocs 266±24(a), Brilliant Crios 259±21(ab); Tetric CAD 254±15(ab); Katana Avencia 241±29(bc); Cerasmart 221±24(cd); Lava Ultimate 196±23(de); Block HC 139±10(e). All the tested materials had flexural strengths greater than 100 MPa, thereby satisfying the requirements of ISO standards for polymer-based materials. For all the tested materials the Weibull characteristic strength was greater than 100 MPa. Weibull modulus ranged between 21.20 (Tetric CAD) and 9.09 (Katana Avencia). Clinical significance: Even though all the CAD-CAM polymer-based materials marketed in blocks tested in the present study satisfy the requirements of ISO standard for polymer-based materials, their flexural resistance differs significantly. The data presented in the study may be helpful to clinicians for selecting the most appropriate materials for each clinical case.

Vichi, A., Goracci, C., Carrabba, M., Tozzi, G., Louca, C. (2020). Flexural resistance of CAD-CAM blocks. Part 3: Polymer-based restorative materials for permanent restorations. AMERICAN JOURNAL OF DENTISTRY, 33(5), 243-247.

Flexural resistance of CAD-CAM blocks. Part 3: Polymer-based restorative materials for permanent restorations

Goracci, Cecilia;
2020-01-01

Abstract

Purpose: Concurrently with the growing interest in CAD-CAM systems, several new materials of different chemical nature have become available. As an alternative to ceramics, numerous polymer-based materials have recently been proposed for permanent prosthetic restorations. Aim of this study was to test the CAD-CAM polymer-based materials available on the market, comparing mean flexural strength, Weibull characteristic strength and Weibull modulus. Methods: Seven types of polymer-based blocks were tested: Lava Ultimate, 3M; Brilliant Crios, Coltene; Cerasmart, GC; Block HC, Shofu; Katana Avencia, Noritake; Grandio Blocs, Voco; Tetric CAD, and Ivoclar-Vivadent. Specimens were cut out from blocks, finished, polished, and tested in a three-point bending test apparatus until failure (n=30). Flexural strength, Weibull characteristic strength, and Weibull modulus were calculated. Flexural strength data were statistically analyzed. ANOVA on Ranks was applied, followed by the Dunn's test for post hoc comparisons (P= 0.05). Results: Flexural strength values (MPa) were measured (mean±standard deviation). Different letters in parentheses label statistically significant differences: Grandio Blocs 266±24(a), Brilliant Crios 259±21(ab); Tetric CAD 254±15(ab); Katana Avencia 241±29(bc); Cerasmart 221±24(cd); Lava Ultimate 196±23(de); Block HC 139±10(e). All the tested materials had flexural strengths greater than 100 MPa, thereby satisfying the requirements of ISO standards for polymer-based materials. For all the tested materials the Weibull characteristic strength was greater than 100 MPa. Weibull modulus ranged between 21.20 (Tetric CAD) and 9.09 (Katana Avencia). Clinical significance: Even though all the CAD-CAM polymer-based materials marketed in blocks tested in the present study satisfy the requirements of ISO standard for polymer-based materials, their flexural resistance differs significantly. The data presented in the study may be helpful to clinicians for selecting the most appropriate materials for each clinical case.
2020
Vichi, A., Goracci, C., Carrabba, M., Tozzi, G., Louca, C. (2020). Flexural resistance of CAD-CAM blocks. Part 3: Polymer-based restorative materials for permanent restorations. AMERICAN JOURNAL OF DENTISTRY, 33(5), 243-247.
File in questo prodotto:
File Dimensione Formato  
Vichi AJD Oct 2020.pdf

non disponibili

Tipologia: PDF editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 625.31 kB
Formato Adobe PDF
625.31 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/1277260