Objectives: This study sought to evaluate 1-year safety and efficacy of dual-layered mesh-covered carotid stent systems (DLS) for carotid artery stenting (CAS). Background: Small clinical studies evaluating 1-year outcomes of CAS performed with 2 available DLS, Roadsaver (RS) (Terumo Corp., Tokyo, Japan) and CGuard (CG) (InspireMD, Boston, Massachusetts), have been published. Methods: The authors performed an individual patient–level meta-analysis including studies enrolling more than 100 CAS with DLS. The primary endpoint was the death and stroke rate; secondary endpoints were restenosis and in-stent thrombosis rates at 1 year. Results: Patients were divided into 2 groups according to DLS (RS n = 250; CG n = 306). At 1 year, 11 patients died (1.97%), 7 patients in the group RS (2.8%) and 4 patients in the CG one (1.31%); and 10 strokes occurred, 4 in the group RS (1.6%) and 6 in the CG one (1.96%). Overall death and stroke rate was 3.77% (n = 21), 11 events in the group RS group (4.4%) and 10 in the CG group (3.27%). Symptomatic status was the only predictor of death and or stroke. At 1 year, restenosis occurred in 12 patients (2.1%), 10 in the group RS (4%) and 2 in the CG one (0.65%) (p = 0.007). In-stent thrombosis occurred in 1 patient (0.18%) in the CG group (0.32%). RS use was the only independent predictor of restenosis. Conclusions: This study suggests that DLS use for CAS is associated with a low 1-year death and stroke rate, and the specific DLS stent used could affect the restenosis rate.
Stabile, E., de Donato, G., Musialek, P., Deloose, K., Nerla, R., Sirignano, P., et al. (2020). Use of Dual-Layered Stents for Carotid Artery Angioplasty: 1-Year Results of a Patient-Based Meta-Analysis. JACC: CARDIOVASCULAR INTERVENTIONS, 13(14), 1709-1715 [10.1016/j.jcin.2020.03.048].
Use of Dual-Layered Stents for Carotid Artery Angioplasty: 1-Year Results of a Patient-Based Meta-Analysis
de Donato G.;Setacci C.;
2020-01-01
Abstract
Objectives: This study sought to evaluate 1-year safety and efficacy of dual-layered mesh-covered carotid stent systems (DLS) for carotid artery stenting (CAS). Background: Small clinical studies evaluating 1-year outcomes of CAS performed with 2 available DLS, Roadsaver (RS) (Terumo Corp., Tokyo, Japan) and CGuard (CG) (InspireMD, Boston, Massachusetts), have been published. Methods: The authors performed an individual patient–level meta-analysis including studies enrolling more than 100 CAS with DLS. The primary endpoint was the death and stroke rate; secondary endpoints were restenosis and in-stent thrombosis rates at 1 year. Results: Patients were divided into 2 groups according to DLS (RS n = 250; CG n = 306). At 1 year, 11 patients died (1.97%), 7 patients in the group RS (2.8%) and 4 patients in the CG one (1.31%); and 10 strokes occurred, 4 in the group RS (1.6%) and 6 in the CG one (1.96%). Overall death and stroke rate was 3.77% (n = 21), 11 events in the group RS group (4.4%) and 10 in the CG group (3.27%). Symptomatic status was the only predictor of death and or stroke. At 1 year, restenosis occurred in 12 patients (2.1%), 10 in the group RS (4%) and 2 in the CG one (0.65%) (p = 0.007). In-stent thrombosis occurred in 1 patient (0.18%) in the CG group (0.32%). RS use was the only independent predictor of restenosis. Conclusions: This study suggests that DLS use for CAS is associated with a low 1-year death and stroke rate, and the specific DLS stent used could affect the restenosis rate.| File | Dimensione | Formato | |
|---|---|---|---|
|
Use of Dual-Layered-DeDonato-2020.pdf
non disponibili
Descrizione: Free full-text sul sito dell'editore
Tipologia:
PDF editoriale
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
661.69 kB
Formato
Adobe PDF
|
661.69 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11365/1276737
