Background: Sensors that are sensitive to volatile organic compounds, and thus able to monitor the conservation state of food, are precious because they work non-destructively and allow avoiding direct contact with the food, ensuring hygienic conditions. In particular, the monitoring of rancidity would solve a widespread issue in food storage. Results: The sensor discussed here is produced utilizing a novel three-dimensional arrangement of graphene, which is grown on a crystalline silicon carbide wafer previously porousified by chemical etching. This approach allows a very high surface-to-volume ratio. Furthermore, the structure of the sensor surface features a large number of edges, dangling bounds, and active sites, which make the sensor, on a chemically robust skeleton, chemically active, particularly to hydrogenated molecules. The interaction of the sensor with such compounds is read out by measuring the sensor resistance in a four-wire configuration. The sensor performance has been assessed on three hazelnut samples: sound, spoiled, and stink bug hazelnuts. A resistance variation of about ∆R = 0.13 ± 0.02 Ω between sound and damaged hazelnuts has been detected. Conclusions: Our measurements confirm the ability of the sensor to discriminate between sound and damaged hazelnuts. The sensor signal is stable for days, providing the possibility to use this sensor for the monitoring of the storage state of fats and foods in general. © 2023 Society of Chemical Industry.

Veronesi, S., Vlamidis, Y., Ferbel, L., Marinelli, C., Sanmartin, C., Taglieri, I., et al. (2023). Three-dimensional graphene on a nano-porous 4H-silicon carbide backbone: a novel material for food sensing applications. JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE [10.1002/jsfa.13118].

Three-dimensional graphene on a nano-porous 4H-silicon carbide backbone: a novel material for food sensing applications

Veronesi, Stefano
Writing – Original Draft Preparation
;
Vlamidis, Ylea
Investigation
;
Marinelli, Carmela
Investigation
;
2023-01-01

Abstract

Background: Sensors that are sensitive to volatile organic compounds, and thus able to monitor the conservation state of food, are precious because they work non-destructively and allow avoiding direct contact with the food, ensuring hygienic conditions. In particular, the monitoring of rancidity would solve a widespread issue in food storage. Results: The sensor discussed here is produced utilizing a novel three-dimensional arrangement of graphene, which is grown on a crystalline silicon carbide wafer previously porousified by chemical etching. This approach allows a very high surface-to-volume ratio. Furthermore, the structure of the sensor surface features a large number of edges, dangling bounds, and active sites, which make the sensor, on a chemically robust skeleton, chemically active, particularly to hydrogenated molecules. The interaction of the sensor with such compounds is read out by measuring the sensor resistance in a four-wire configuration. The sensor performance has been assessed on three hazelnut samples: sound, spoiled, and stink bug hazelnuts. A resistance variation of about ∆R = 0.13 ± 0.02 Ω between sound and damaged hazelnuts has been detected. Conclusions: Our measurements confirm the ability of the sensor to discriminate between sound and damaged hazelnuts. The sensor signal is stable for days, providing the possibility to use this sensor for the monitoring of the storage state of fats and foods in general. © 2023 Society of Chemical Industry.
2023
Veronesi, S., Vlamidis, Y., Ferbel, L., Marinelli, C., Sanmartin, C., Taglieri, I., et al. (2023). Three-dimensional graphene on a nano-porous 4H-silicon carbide backbone: a novel material for food sensing applications. JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE [10.1002/jsfa.13118].
File in questo prodotto:
File Dimensione Formato  
18 J Sci Food Agric - 2023 - Veronesi - Three‐dimensional graphene on a nano‐porous 4H‐silicon carbide backbone a novel.pdf

non disponibili

Tipologia: PDF editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.44 MB
Formato Adobe PDF
1.44 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/1259856