Aims: Pancreatic ductal adenocarcinomas (PDACs) are increasingly being treated with neoadjuvant therapy. However, the American Joint Committee on Cancer (AJCC) 8th edition T staging based on tumour size does not reflect treatment effect, which often results in multiple, small foci of residual tumour in a background of mass-forming fibrosis. Thus, we evaluated the performance of AJCC 8th edition T staging in predicting patient outcomes by the use of a microscopic tumour size measurement method. Methods and results: One hundred and six post-neoadjuvant therapy pancreatectomies were reviewed, and all individual tumour foci were measured. T stages based on gross size with microscopic adjustment (GS) and the largest single microscopic focus size (MFS) were examined in association with clinicopathological variables and patient outcomes. Sixty-three of 106 (59%) were locally advanced; 78% received FOLFIRINOX treatment. The average GS and MFS were 25 mm and 11 mm, respectively; nine cases each were classified as T0, 35 and 85 cases as T1, 42 and 12 cases as T2, and 20 and 0 cases as T3, based on the GS and the MFS, respectively. Higher GS-based and MFS-based T stages were significantly associated with higher tumour regression grade, lymphovascular and perineural invasion, and higher N stage. Furthermore, higher MFS-based T stage was significantly associated with shorter disease-free survival (DFS) (P < 0.001) and shorter overall survival (OS) (P = 0.002). GS was significantly associated with OS (P = 0.046), but not with DFS. Conclusions: In post-neoadjuvant therapy PDAC resections, MFS-based T staging is superior to GS-based T staging for predicting patient outcomes, suggesting that microscopic measurements have clinical utility beyond the conventional use of GS measurements alone. © 2020 John Wiley & Sons Ltd
Zhang, M.l., Kem, M., Rodrigues, C., Sandini, M., Ciprani, D., Hank, T., et al. (2020). Microscopic size measurements in post-neoadjuvant therapy resections of pancreatic ductal adenocarcinoma (PDAC) predict patient outcomes. HISTOPATHOLOGY, 77(1), 144-155 [10.1111/his.14067].
Microscopic size measurements in post-neoadjuvant therapy resections of pancreatic ductal adenocarcinoma (PDAC) predict patient outcomes
Sandini M;
2020-01-01
Abstract
Aims: Pancreatic ductal adenocarcinomas (PDACs) are increasingly being treated with neoadjuvant therapy. However, the American Joint Committee on Cancer (AJCC) 8th edition T staging based on tumour size does not reflect treatment effect, which often results in multiple, small foci of residual tumour in a background of mass-forming fibrosis. Thus, we evaluated the performance of AJCC 8th edition T staging in predicting patient outcomes by the use of a microscopic tumour size measurement method. Methods and results: One hundred and six post-neoadjuvant therapy pancreatectomies were reviewed, and all individual tumour foci were measured. T stages based on gross size with microscopic adjustment (GS) and the largest single microscopic focus size (MFS) were examined in association with clinicopathological variables and patient outcomes. Sixty-three of 106 (59%) were locally advanced; 78% received FOLFIRINOX treatment. The average GS and MFS were 25 mm and 11 mm, respectively; nine cases each were classified as T0, 35 and 85 cases as T1, 42 and 12 cases as T2, and 20 and 0 cases as T3, based on the GS and the MFS, respectively. Higher GS-based and MFS-based T stages were significantly associated with higher tumour regression grade, lymphovascular and perineural invasion, and higher N stage. Furthermore, higher MFS-based T stage was significantly associated with shorter disease-free survival (DFS) (P < 0.001) and shorter overall survival (OS) (P = 0.002). GS was significantly associated with OS (P = 0.046), but not with DFS. Conclusions: In post-neoadjuvant therapy PDAC resections, MFS-based T staging is superior to GS-based T staging for predicting patient outcomes, suggesting that microscopic measurements have clinical utility beyond the conventional use of GS measurements alone. © 2020 John Wiley & Sons LtdFile | Dimensione | Formato | |
---|---|---|---|
Microscopic size measurements in post-neoadjuvant therapy-Zhang-2020.pdf
non disponibili
Descrizione: Articolo
Tipologia:
PDF editoriale
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
3.64 MB
Formato
Adobe PDF
|
3.64 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11365/1248954