The purpose of this case report is to present a deviation analysis made to evaluate the accuracy and reproducibility of virtual surgical planning - computer-aided design - computer-aided manufacturing (CAD/CAM) technology. These techniques were used to programme and perform both demolitive and reconstructive surgery in an 18-year-old man treated for a mandibular ameloblastoma. Total body CT scan and CT angiography were performed before the surgery. DICOM-format data were captured and a planning was performed using CAD/CAM technology. After the surgery, DICOM files of a postoperative CT scan were evaluated to assess the accuracy of the reconstruction. The deviation of the postoperative result from what was planned was indicated with different colours in a mandible mapper and changes in condylar and angular position between 0.5 mm and 2 mm were observed. A standardised method to evaluate accuracy or efficiency of CAD/CAM technology is still not available, nevertheless, since the patient has a good functional or aesthetic recover, the authors are satisfied with the results.

Gennaro, P., Cascino, F., Pignataro, L.V., Gabriele, G. (2022). Deviation analysis in custom-made mandibular reconstruction: how to evaluate results. BMJ CASE REPORT, 15(7) [10.1136/bcr-2021-247847].

Deviation analysis in custom-made mandibular reconstruction: how to evaluate results

Gennaro P.;Cascino F.;Pignataro L. V.;Gabriele G.
2022-01-01

Abstract

The purpose of this case report is to present a deviation analysis made to evaluate the accuracy and reproducibility of virtual surgical planning - computer-aided design - computer-aided manufacturing (CAD/CAM) technology. These techniques were used to programme and perform both demolitive and reconstructive surgery in an 18-year-old man treated for a mandibular ameloblastoma. Total body CT scan and CT angiography were performed before the surgery. DICOM-format data were captured and a planning was performed using CAD/CAM technology. After the surgery, DICOM files of a postoperative CT scan were evaluated to assess the accuracy of the reconstruction. The deviation of the postoperative result from what was planned was indicated with different colours in a mandible mapper and changes in condylar and angular position between 0.5 mm and 2 mm were observed. A standardised method to evaluate accuracy or efficiency of CAD/CAM technology is still not available, nevertheless, since the patient has a good functional or aesthetic recover, the authors are satisfied with the results.
2022
Gennaro, P., Cascino, F., Pignataro, L.V., Gabriele, G. (2022). Deviation analysis in custom-made mandibular reconstruction: how to evaluate results. BMJ CASE REPORT, 15(7) [10.1136/bcr-2021-247847].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/1243155