Aimwe sought to test the inter-center reproducibility of 16 echo laboratories involved in the EACVI-Afib Echo Europe. MethodsThis was done on a dedicated setting of 10 patients with sinus rhythm (SR) and 10 with persistent atrial fibrillation (AF), collected by the Principal Investigator. Images and loops of echo-exams were stored and made available for labs. The tested measurements included main echo-Doppler parameters, global longitudinal strain (GLS) and peak atrial longitudinal strain (PALS). ResultsSingle measures interclass correlation coefficients (ICCs) of left ventricular mass and ejection fraction were suboptimal in both patients with SR and AF. Among diastolic parameters, ICCs of deceleration time were poor, in particular in AF (=.50). ICCs of left atrial size and function, besides optimal in AF, showed an acceptable despite moderate concordance in SR. ICC of GLS was .81 and .78 in SR and AF respectively. ICCs of PALS were suitable but lower in 4-chamber than in 2-chamber view. By depicting the boxplot of the 16 laboratories, GLS distribution was completely homogeneous in SR, whereas GLS of AF and PALS of both SR and AF presented a limited number of outliers. GLS mean & PLUSMN; SE of the 16 labs was 19.7 & PLUSMN; .36 (95% CI: 18.8-20.4) in SR and 16.5 & PLUSMN; .29 (95% CI: 15.9-17.1) in AF, whereas PALS mean & PLUSMN; SE was 43.8 & PLUSMN; .70 (95% CI: 42.3-45.3) and 10.2 & PLUSMN; .32 (95% CI: 9.5-10.9) respectively. ConclusionWhile the utilization of some standard-echo variables should be discouraged in registries, the application of GLS and PALS could be largely promoted because their superior reproducibility, even in AF.

Santoro, C., Donal, E., Magne, J., Sade, L.E., Penicka, M., Katbeh, A., et al. (2023). Inter-center reproducibility of standard and advanced echocardiographic parameters in the EACVI-AFib echo registry. ECHOCARDIOGRAPHY [10.1111/echo.15640].

Inter-center reproducibility of standard and advanced echocardiographic parameters in the EACVI-AFib echo registry

Cameli, Matteo;Mandoli, Giulia;Galderisi, Maurizio
2023-01-01

Abstract

Aimwe sought to test the inter-center reproducibility of 16 echo laboratories involved in the EACVI-Afib Echo Europe. MethodsThis was done on a dedicated setting of 10 patients with sinus rhythm (SR) and 10 with persistent atrial fibrillation (AF), collected by the Principal Investigator. Images and loops of echo-exams were stored and made available for labs. The tested measurements included main echo-Doppler parameters, global longitudinal strain (GLS) and peak atrial longitudinal strain (PALS). ResultsSingle measures interclass correlation coefficients (ICCs) of left ventricular mass and ejection fraction were suboptimal in both patients with SR and AF. Among diastolic parameters, ICCs of deceleration time were poor, in particular in AF (=.50). ICCs of left atrial size and function, besides optimal in AF, showed an acceptable despite moderate concordance in SR. ICC of GLS was .81 and .78 in SR and AF respectively. ICCs of PALS were suitable but lower in 4-chamber than in 2-chamber view. By depicting the boxplot of the 16 laboratories, GLS distribution was completely homogeneous in SR, whereas GLS of AF and PALS of both SR and AF presented a limited number of outliers. GLS mean & PLUSMN; SE of the 16 labs was 19.7 & PLUSMN; .36 (95% CI: 18.8-20.4) in SR and 16.5 & PLUSMN; .29 (95% CI: 15.9-17.1) in AF, whereas PALS mean & PLUSMN; SE was 43.8 & PLUSMN; .70 (95% CI: 42.3-45.3) and 10.2 & PLUSMN; .32 (95% CI: 9.5-10.9) respectively. ConclusionWhile the utilization of some standard-echo variables should be discouraged in registries, the application of GLS and PALS could be largely promoted because their superior reproducibility, even in AF.
2023
Santoro, C., Donal, E., Magne, J., Sade, L.E., Penicka, M., Katbeh, A., et al. (2023). Inter-center reproducibility of standard and advanced echocardiographic parameters in the EACVI-AFib echo registry. ECHOCARDIOGRAPHY [10.1111/echo.15640].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/1236614
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo