Strengthening of Resilon-filled roots via an adhesive interface should be reflected by improvement in the interfacial strength and dislocation resistance between the root fillings and intraradicular dentin. This study compared the interfacial strengths of Resilon/Epiphany and gutta-percha/AH Plus using a thin-slice push-out test design. Failure modes of root slices after push-out testing were examined with environmental scanning electron microscopy. The gutta-percha group exhibited significantly higher interfacial strength than the Resilon group, when premature failures that occurred in Resilon root slices were included in the statistical analysis. The gutta-percha root slices failed exclusively along the gutta-percha/sealer interface. The Resilon root slices failed predominantly along the sealer/dentin interface with recognizable, fractured resin tags. Detachment of the Resilon from the Epiphany sealer was also surprisingly observed in some specimens. The similarly low interfacial strengths achieved with both types of root filling challenges the concept of strengthening root-filled teeth with the new endodontic material. Copyright © 2005 by the American Association of Endodontists.

Gesi, A., Raffaelli, O., Goracci, C., Pashley, D.H., Tay, F.R., Ferrari, M. (2005). Interfacial strength of Resilon and gutta-percha to intraradicular dentin. JOURNAL OF ENDODONTICS, 31(11), 809-813 [10.1097/01.don.0000158230.15853.b7].

Interfacial strength of Resilon and gutta-percha to intraradicular dentin

GORACCI C.;FERRARI M.
2005-01-01

Abstract

Strengthening of Resilon-filled roots via an adhesive interface should be reflected by improvement in the interfacial strength and dislocation resistance between the root fillings and intraradicular dentin. This study compared the interfacial strengths of Resilon/Epiphany and gutta-percha/AH Plus using a thin-slice push-out test design. Failure modes of root slices after push-out testing were examined with environmental scanning electron microscopy. The gutta-percha group exhibited significantly higher interfacial strength than the Resilon group, when premature failures that occurred in Resilon root slices were included in the statistical analysis. The gutta-percha root slices failed exclusively along the gutta-percha/sealer interface. The Resilon root slices failed predominantly along the sealer/dentin interface with recognizable, fractured resin tags. Detachment of the Resilon from the Epiphany sealer was also surprisingly observed in some specimens. The similarly low interfacial strengths achieved with both types of root filling challenges the concept of strengthening root-filled teeth with the new endodontic material. Copyright © 2005 by the American Association of Endodontists.
2005
Gesi, A., Raffaelli, O., Goracci, C., Pashley, D.H., Tay, F.R., Ferrari, M. (2005). Interfacial strength of Resilon and gutta-percha to intraradicular dentin. JOURNAL OF ENDODONTICS, 31(11), 809-813 [10.1097/01.don.0000158230.15853.b7].
File in questo prodotto:
File Dimensione Formato  
Gesijoe05.pdf

non disponibili

Tipologia: Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 883.76 kB
Formato Adobe PDF
883.76 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/12322
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo