Background We aimed to verify the usefulness of electroencephalographic (EEG) activity recording (that is mandatory according to the Italian law), in addition to two clinical evaluations spaced 6 h, among the procedures of brain death determination (BDD) in adult individuals. Methods The study is a monocentric, retrospective analysis of all BDDs performed in the last 10 years at Policlinico Le Scotte in Siena (Italy). Results Of the 428 cases revised (mean age 67.6 ± 15.03 years; range 24–92 years), 225 were males and 203 females. In total, 212 out of 428 patients (49.5%) were donors. None of the BDD procedures were interrupted due to the reappearance of EEG activity (neither for clinical reasons) at any sampling time, with the exception of one case that was considered a false negative at critical reinspection of the EEG. In 6/428 cases (1.4%), a cardiac arrest occurred during the 6 h between the first and second evaluation, thus missing the opportunity to take organs from these patients because the BDD procedure was not completed. Conclusions Once the initial clinical examination before convening the BDD Commission has ascertained the absence of brainstem reflexes and of spontaneous breathing, and these clinical findings are supported by a flat EEG recording, the repetition of a 30-min EEG twice over a 6 h period seems not to add additional useful information to clinical findings. Current data, if confirmed in other centers and possibly in prospective studies, may help to promote a scientific and bioethical debate in Italy, as well as in other countries where the EEG is still mandatory, for eventually pdating the procedures of BDD. © 2022, The Author(s).

Rossi, S., Mazza, G., Del Testa, M., Giannotta, A., Bartalini, S., Testani, E., et al. (2023). Suitability of electroencephalography in brain death determination: a monocentric, 10-year retrospective, observational investigation of 428 cases. NEUROLOGICAL SCIENCES, 44(4), 1369-1373 [10.1007/s10072-022-06547-1].

Suitability of electroencephalography in brain death determination: a monocentric, 10-year retrospective, observational investigation of 428 cases

Simone Rossi;Gionathan Mazza;Alessandro Giannotta;Sabina Bartalini;Mario Gabbrielli;Giampaolo Vatti;Sabino Scolletta
2023-01-01

Abstract

Background We aimed to verify the usefulness of electroencephalographic (EEG) activity recording (that is mandatory according to the Italian law), in addition to two clinical evaluations spaced 6 h, among the procedures of brain death determination (BDD) in adult individuals. Methods The study is a monocentric, retrospective analysis of all BDDs performed in the last 10 years at Policlinico Le Scotte in Siena (Italy). Results Of the 428 cases revised (mean age 67.6 ± 15.03 years; range 24–92 years), 225 were males and 203 females. In total, 212 out of 428 patients (49.5%) were donors. None of the BDD procedures were interrupted due to the reappearance of EEG activity (neither for clinical reasons) at any sampling time, with the exception of one case that was considered a false negative at critical reinspection of the EEG. In 6/428 cases (1.4%), a cardiac arrest occurred during the 6 h between the first and second evaluation, thus missing the opportunity to take organs from these patients because the BDD procedure was not completed. Conclusions Once the initial clinical examination before convening the BDD Commission has ascertained the absence of brainstem reflexes and of spontaneous breathing, and these clinical findings are supported by a flat EEG recording, the repetition of a 30-min EEG twice over a 6 h period seems not to add additional useful information to clinical findings. Current data, if confirmed in other centers and possibly in prospective studies, may help to promote a scientific and bioethical debate in Italy, as well as in other countries where the EEG is still mandatory, for eventually pdating the procedures of BDD. © 2022, The Author(s).
2023
Rossi, S., Mazza, G., Del Testa, M., Giannotta, A., Bartalini, S., Testani, E., et al. (2023). Suitability of electroencephalography in brain death determination: a monocentric, 10-year retrospective, observational investigation of 428 cases. NEUROLOGICAL SCIENCES, 44(4), 1369-1373 [10.1007/s10072-022-06547-1].
File in questo prodotto:
File Dimensione Formato  
68160c1b-29a3-4e73-8612-cf1115714f51(1).pdf

accesso aperto

Descrizione: Articolo
Tipologia: PDF editoriale
Licenza: Creative commons
Dimensione 509.97 kB
Formato Adobe PDF
509.97 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/1222376