Post can be placed immediately after the completion of the endodontic procedure or at a later stage after setting of the sealer. In this in vitro study, post space preparation and post cementation were performed immediately (group 1), 24 h (group 2), and 7 days (group 3) after root filling. A control group with no root canal obturation was included (group 4). Each group was further divided into three subgroups, according to the post type and to the materials used for luting the post. A push-out test was performed to evaluate post-root canal dentin interfacial strength. Differences among experimental groups were analyzed with two-way ANOVA and the Tukey test. Significant differences (p < 0.05) in interfacial strengths were observed for the factors post cementation interval and post type. Clinicians should be careful in performing immediate cementation of fiber posts, as delayed cementation shows higher post-dentin interfacial strengths irrespective of the post type.

Vano, M., Cury, A.H., Goracci, C., Chieffi, N., Gabriele, M., Tay, F.R., et al. (2006). The effect of immediate versus delayed cementation on the retention of different types of fiber post in canals obturated using a eugenol sealer. JOURNAL OF ENDODONTICS, 32(9), 882-885 [10.1016/j.joen.2006.02.025].

The effect of immediate versus delayed cementation on the retention of different types of fiber post in canals obturated using a eugenol sealer

GORACCI C.;FERRARI M.
2006-01-01

Abstract

Post can be placed immediately after the completion of the endodontic procedure or at a later stage after setting of the sealer. In this in vitro study, post space preparation and post cementation were performed immediately (group 1), 24 h (group 2), and 7 days (group 3) after root filling. A control group with no root canal obturation was included (group 4). Each group was further divided into three subgroups, according to the post type and to the materials used for luting the post. A push-out test was performed to evaluate post-root canal dentin interfacial strength. Differences among experimental groups were analyzed with two-way ANOVA and the Tukey test. Significant differences (p < 0.05) in interfacial strengths were observed for the factors post cementation interval and post type. Clinicians should be careful in performing immediate cementation of fiber posts, as delayed cementation shows higher post-dentin interfacial strengths irrespective of the post type.
2006
Vano, M., Cury, A.H., Goracci, C., Chieffi, N., Gabriele, M., Tay, F.R., et al. (2006). The effect of immediate versus delayed cementation on the retention of different types of fiber post in canals obturated using a eugenol sealer. JOURNAL OF ENDODONTICS, 32(9), 882-885 [10.1016/j.joen.2006.02.025].
File in questo prodotto:
File Dimensione Formato  
vanojoe06.pdf

non disponibili

Tipologia: Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 94.96 kB
Formato Adobe PDF
94.96 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/12209
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo