BACKGROUND: This study describes the clinical and echocardiographic outcomes in a large single-center cohort of patients who underwent aortic valve replacement (AVR) with a sutureless Perceval (LivaNova, Milan, Italy) aortic bioprosthesis. METHODS: Between March 2011 and December 2015, 617 patients underwent AVR with a Perceval bioprosthesis. The mean age was 76 ± 7 years, 388 patients were female (63%), and the mean European System for Cardiac Operative Risk Evaluation (EuroSCORE) II was 6.2% ± 5.4%. Concomitant procedures were mitral valve surgery (n = 74), tricuspid valve repair (n = 22), coronary artery bypass grafting (n = 42), myectomy (n = 3), and ascending aorta replacement (n = 2). RESULTS: The 30-day mortality rate was 1.9% (12 of 617). A total of 475 of 516 (92%) patients who had isolated AVR underwent minimally invasive surgery with an upper ministernotomy (n = 81) or a right anterior minithoracotomy (n = 394) approach. Cardiopulmonary bypass and aortic cross-clamp times were 81.7 ± 29.1 minutes and 50.5 ± 19.8 minutes for isolated AVR and 139.7 ± 51.5 minutes and 91.5 ± 29.5 minutes for combined procedures, respectively. At mean follow-up of 16.3 months (range, 0 to 51.9 months), the survival rate was 91.3%, the rate of freedom from reoperation was 99%, and the mean transvalvular pressure gradient was 11.9 ± 5.4 mm Hg. Left ventricular ejection fraction increased from 53.6% ± 8.4% to 54.5% ± 4.8% (p = 0.40), left ventricular mass decreased from 146.5 to 112.6 g/m2 (p < 0.001), and moderate paravalvular leakage occurred in 3 patients without hemolysis who did not require any treatment. CONCLUSIONS: AVR with the Perceval bioprosthesis is associated with low mortality rates and excellent hemodynamic performance. Sutureless technology may reduce operative times, especially in combined procedures, and may make minimally invasive AVR more easily reproducible.

Concistrè, G., Chiaramonti, F., Bianchi, G., Cerillo, A., Murzi, M., Margaryan, R., et al. (2018). Aortic Valve Replacement With Perceval Bioprosthesis: Single-Center Experience With 617 Implants. THE ANNALS OF THORACIC SURGERY, 1(105), 40-46 [10.1016/j.athoracsur.2017.05.080].

Aortic Valve Replacement With Perceval Bioprosthesis: Single-Center Experience With 617 Implants

Bianchi G
Formal Analysis
;
2018-01-01

Abstract

BACKGROUND: This study describes the clinical and echocardiographic outcomes in a large single-center cohort of patients who underwent aortic valve replacement (AVR) with a sutureless Perceval (LivaNova, Milan, Italy) aortic bioprosthesis. METHODS: Between March 2011 and December 2015, 617 patients underwent AVR with a Perceval bioprosthesis. The mean age was 76 ± 7 years, 388 patients were female (63%), and the mean European System for Cardiac Operative Risk Evaluation (EuroSCORE) II was 6.2% ± 5.4%. Concomitant procedures were mitral valve surgery (n = 74), tricuspid valve repair (n = 22), coronary artery bypass grafting (n = 42), myectomy (n = 3), and ascending aorta replacement (n = 2). RESULTS: The 30-day mortality rate was 1.9% (12 of 617). A total of 475 of 516 (92%) patients who had isolated AVR underwent minimally invasive surgery with an upper ministernotomy (n = 81) or a right anterior minithoracotomy (n = 394) approach. Cardiopulmonary bypass and aortic cross-clamp times were 81.7 ± 29.1 minutes and 50.5 ± 19.8 minutes for isolated AVR and 139.7 ± 51.5 minutes and 91.5 ± 29.5 minutes for combined procedures, respectively. At mean follow-up of 16.3 months (range, 0 to 51.9 months), the survival rate was 91.3%, the rate of freedom from reoperation was 99%, and the mean transvalvular pressure gradient was 11.9 ± 5.4 mm Hg. Left ventricular ejection fraction increased from 53.6% ± 8.4% to 54.5% ± 4.8% (p = 0.40), left ventricular mass decreased from 146.5 to 112.6 g/m2 (p < 0.001), and moderate paravalvular leakage occurred in 3 patients without hemolysis who did not require any treatment. CONCLUSIONS: AVR with the Perceval bioprosthesis is associated with low mortality rates and excellent hemodynamic performance. Sutureless technology may reduce operative times, especially in combined procedures, and may make minimally invasive AVR more easily reproducible.
2018
Concistrè, G., Chiaramonti, F., Bianchi, G., Cerillo, A., Murzi, M., Margaryan, R., et al. (2018). Aortic Valve Replacement With Perceval Bioprosthesis: Single-Center Experience With 617 Implants. THE ANNALS OF THORACIC SURGERY, 1(105), 40-46 [10.1016/j.athoracsur.2017.05.080].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/1219314
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo