Objectives. To verify whether substrate, shape, or thickness of microtensile specimens have a significant influence on their measured bond strength. Methods. Sixty-four extracted molars provided microtensile specimens, which were prepared on enamel and dentin, in different shapes and thicknesses. The teeth were randomly divided into 16 groups (n = 4). Groups 1-8 included hourglass-shaped specimens. In Groups 1-4 specimens were prepared from enamel and in a thickness at the bonding interface of 0.5mm×0.5 mm, 1mm×1 mm, 1.5mm×1.5 mm, and 2mm×2 mm, respectively. In these same thicknesses, hourglasses were trimmed in Groups 5-8, but the specimens were prepared from dentin. Groups 9-16 included specimens obtained following the non-trimming technique. Groups 9-12 provided enamel sticks in the four evaluated thicknesses. In these same thicknesses and shape but from dentin were cut the specimens of Groups 13-16. Two specimens from each group were viewed using a scanning electron microscope. On the other ones, microtensile bond strength was measured and the values were statistically analyzed. Results. Substrate, shape, and thickness of the specimens had a significant effect on their recorded bond strength (p<0.05). Higher bond strength values were recorded by dentin versus enamel specimens and by sticks versus hourglasses. Also, bond strength decreased as specimen thickness increased. SEM analysis revealed that the trimmed specimens, especially if from enamel, often exhibited lines of fracture in the area of action of the bur. Significance. It seems advisable to avoid the trimming action particularly on enamel specimens. If the hourglass shape is preferred, the cross-sectional area should not exceed 1mm×1 mm. © 2004 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Goracci, C., Sadek, F.T., Monticelli, F., Cardoso, P.E., Ferrari, M. (2004). Influence of substrate, shape, and thickness on microtensile specimens' structural integrity and their measured bond strengths. DENTAL MATERIALS, 20(7), 643-654 [10.1016/j.dental.2003.08.009].

Influence of substrate, shape, and thickness on microtensile specimens' structural integrity and their measured bond strengths

GORACCI C.;FERRARI M.
2004-01-01

Abstract

Objectives. To verify whether substrate, shape, or thickness of microtensile specimens have a significant influence on their measured bond strength. Methods. Sixty-four extracted molars provided microtensile specimens, which were prepared on enamel and dentin, in different shapes and thicknesses. The teeth were randomly divided into 16 groups (n = 4). Groups 1-8 included hourglass-shaped specimens. In Groups 1-4 specimens were prepared from enamel and in a thickness at the bonding interface of 0.5mm×0.5 mm, 1mm×1 mm, 1.5mm×1.5 mm, and 2mm×2 mm, respectively. In these same thicknesses, hourglasses were trimmed in Groups 5-8, but the specimens were prepared from dentin. Groups 9-16 included specimens obtained following the non-trimming technique. Groups 9-12 provided enamel sticks in the four evaluated thicknesses. In these same thicknesses and shape but from dentin were cut the specimens of Groups 13-16. Two specimens from each group were viewed using a scanning electron microscope. On the other ones, microtensile bond strength was measured and the values were statistically analyzed. Results. Substrate, shape, and thickness of the specimens had a significant effect on their recorded bond strength (p<0.05). Higher bond strength values were recorded by dentin versus enamel specimens and by sticks versus hourglasses. Also, bond strength decreased as specimen thickness increased. SEM analysis revealed that the trimmed specimens, especially if from enamel, often exhibited lines of fracture in the area of action of the bur. Significance. It seems advisable to avoid the trimming action particularly on enamel specimens. If the hourglass shape is preferred, the cross-sectional area should not exceed 1mm×1 mm. © 2004 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
2004
Goracci, C., Sadek, F.T., Monticelli, F., Cardoso, P.E., Ferrari, M. (2004). Influence of substrate, shape, and thickness on microtensile specimens' structural integrity and their measured bond strengths. DENTAL MATERIALS, 20(7), 643-654 [10.1016/j.dental.2003.08.009].
File in questo prodotto:
File Dimensione Formato  
DentMat microtensile.pdf

non disponibili

Tipologia: Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 921.47 kB
Formato Adobe PDF
921.47 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/12193
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo