The study was aimed at assessing the influence of the cement manipulation and ultrasounds application on the bonding potential of self-adhesive resin cements to dentin by microtensile bond strength testing and microscopic observations of the interface. Fifty-six standardized mesio-occlusal class II cavities were prepared in extracted third molars. Class II inlays were made using the nano-hybrid resin composite Gradia Forte (GC Corp, Tokyo, Japan), following the manufacturer's instruction. The sample was randomly divided into two groups (n=28) according to the luting technique. Half of the specimens were luted under a static seating pressure (P), while the other ones were cemented under vibration (V). The inlays were luted using the following self-adhesive resin cements: G-Cem (G, GC Corp., Tokyo, Japan) Automix (GA) and Capsule (GC); RelyX Unicem (RU, 3 M ESPE, Seefeld, Germany) Clicker (RUC) and Aplicap (RUA). Microtensile sticks and specimens for scanning electron microscope (SEM) observations were obtained from the luted teeth. The interfacial strengths measured for the cements under static pressure or ultrasonic vibration were [ median (interquartile range)]: GC/V 4 (2.3-7.9); GC/P 6.8 (4.1-10.1); GA/V 3 (1.9-6.7); GA/P 1.9 (0-5.1); RUC/V 6.6 (4.6-9.8); RUC/P 4.1 (1.8-6.4); RUA/V 6.2 (2.4-10.4); RUA/P 3.4 (0-5.4). The cement formulation influenced dentin bond strength of G. RU bond strength was affected by the luting technique. SEM analysis revealed a homogeneous structure and reduced porosities for both cements as a result of ultrasonic vibration. RU benefited from the application of ultrasounds, while GC achieved higher bond strengths than GA.
Cantoro, A., Goracci, C., Coniglio, I., Magni, E., Polimeni, A., Ferrari, M. (2011). Influence of ultrasound application on inlays luting with self-adhesive resin cements. CLINICAL ORAL INVESTIGATIONS, 15(5), 617-623 [10.1007/s00784-010-0451-5].
Influence of ultrasound application on inlays luting with self-adhesive resin cements
GORACCI C.;FERRARI M.
2011-01-01
Abstract
The study was aimed at assessing the influence of the cement manipulation and ultrasounds application on the bonding potential of self-adhesive resin cements to dentin by microtensile bond strength testing and microscopic observations of the interface. Fifty-six standardized mesio-occlusal class II cavities were prepared in extracted third molars. Class II inlays were made using the nano-hybrid resin composite Gradia Forte (GC Corp, Tokyo, Japan), following the manufacturer's instruction. The sample was randomly divided into two groups (n=28) according to the luting technique. Half of the specimens were luted under a static seating pressure (P), while the other ones were cemented under vibration (V). The inlays were luted using the following self-adhesive resin cements: G-Cem (G, GC Corp., Tokyo, Japan) Automix (GA) and Capsule (GC); RelyX Unicem (RU, 3 M ESPE, Seefeld, Germany) Clicker (RUC) and Aplicap (RUA). Microtensile sticks and specimens for scanning electron microscope (SEM) observations were obtained from the luted teeth. The interfacial strengths measured for the cements under static pressure or ultrasonic vibration were [ median (interquartile range)]: GC/V 4 (2.3-7.9); GC/P 6.8 (4.1-10.1); GA/V 3 (1.9-6.7); GA/P 1.9 (0-5.1); RUC/V 6.6 (4.6-9.8); RUC/P 4.1 (1.8-6.4); RUA/V 6.2 (2.4-10.4); RUA/P 3.4 (0-5.4). The cement formulation influenced dentin bond strength of G. RU bond strength was affected by the luting technique. SEM analysis revealed a homogeneous structure and reduced porosities for both cements as a result of ultrasonic vibration. RU benefited from the application of ultrasounds, while GC achieved higher bond strengths than GA.File | Dimensione | Formato | |
---|---|---|---|
Cantoro_CLOI10.pdf
non disponibili
Tipologia:
Post-print
Licenza:
NON PUBBLICO - Accesso privato/ristretto
Dimensione
314.99 kB
Formato
Adobe PDF
|
314.99 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11365/12081
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo