: Total cell-associated HIV-1 DNA is a surrogate marker of the HIV-1 reservoir, however, certified systems for its quantification are not available. The Italian HIV DNA Network was launched to validate HIV-1 DNA quantification methods in use at University and Hospital labs. A quality control panel including HIV-1 DNA standards, reconstructed blood samples (RBSs) and DNA from different HIV-1 subtypes was blindly tested by 12 participating labs by quantitative real-time PCR (n = 6), droplet digital PCR (n = 3) or both (n = 3). The median 95% hit rate was 4.6 (3.7-5.5) copies per test and linearity in the tested range was excellent (R2 = 1.000 [1.000-1.000]). The median values obtained across labs were 3,370 (2,287-4,245), 445 (299-498), 59 (40-81) and 7 (6-11) HIV-1 DNA copies, for the 3,584, 448, 56 and 7-copy standards, respectively. With RBSs, measured values were within twofold with respect to the median in two thirds of cases. HIV-1 subtypes were missed (CRF01_AE by 3 labs) or underestimated by > 1 log (subtypes A, C, D, F by one lab; CRF01_AE by one lab; CRF02_AG by one lab). The overall performance was excellent with HIV-1 DNA standards, however detection of different HIV-1 subtypes must be improved.

Vicenti, I., Dragoni, F., Giannini, A., Casabianca, A., Lombardi, F., Di Sante, L., et al. (2022). External quality assessment of HIV-1 DNA quantification assays used in the clinical setting in Italy. SCIENTIFIC REPORTS, 12(1), 3291 [10.1038/s41598-022-07196-2].

External quality assessment of HIV-1 DNA quantification assays used in the clinical setting in Italy

Vicenti, Ilaria;Dragoni, Filippo;Giannini, Alessia;Lombardi, Francesca;Saladini, Francesco;Zazzi, Maurizio
2022-01-01

Abstract

: Total cell-associated HIV-1 DNA is a surrogate marker of the HIV-1 reservoir, however, certified systems for its quantification are not available. The Italian HIV DNA Network was launched to validate HIV-1 DNA quantification methods in use at University and Hospital labs. A quality control panel including HIV-1 DNA standards, reconstructed blood samples (RBSs) and DNA from different HIV-1 subtypes was blindly tested by 12 participating labs by quantitative real-time PCR (n = 6), droplet digital PCR (n = 3) or both (n = 3). The median 95% hit rate was 4.6 (3.7-5.5) copies per test and linearity in the tested range was excellent (R2 = 1.000 [1.000-1.000]). The median values obtained across labs were 3,370 (2,287-4,245), 445 (299-498), 59 (40-81) and 7 (6-11) HIV-1 DNA copies, for the 3,584, 448, 56 and 7-copy standards, respectively. With RBSs, measured values were within twofold with respect to the median in two thirds of cases. HIV-1 subtypes were missed (CRF01_AE by 3 labs) or underestimated by > 1 log (subtypes A, C, D, F by one lab; CRF01_AE by one lab; CRF02_AG by one lab). The overall performance was excellent with HIV-1 DNA standards, however detection of different HIV-1 subtypes must be improved.
2022
Vicenti, I., Dragoni, F., Giannini, A., Casabianca, A., Lombardi, F., Di Sante, L., et al. (2022). External quality assessment of HIV-1 DNA quantification assays used in the clinical setting in Italy. SCIENTIFIC REPORTS, 12(1), 3291 [10.1038/s41598-022-07196-2].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/1192425
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo