Background: The aim of this randomized controlled trial was to evaluate the capability of an IOS (Intra Oral Scanner) device, used in standardized conditions, to detect margins of abutments prepared with knife-edge finishing line located at three different levels in relation to the gingival sulcus. Methods: sixty abutment teeth for treatment with full crowns were selected and randomly divided in three groups accordingly to the depth of the finishing line: Group A: supragingival margin; Group B: 0.5–1.0 mm into the sulcus; Group C: 1.5–2.0 mm into the sulcus. Temporary crowns were placed for two weeks and then digital impressions (Aadva IOS 100, GC, Japan) were made of each abutment. As controls, analog impressions were taken, poured, and scanned using a laboratory scanner (Aadva lab scanner, GC, Japan). Two standard tessellation language (STL) files were generated for each abutment, subsequently processed, and superimposed by Exocad software (Exocad GmbH, Darmstadt, Germany), applying the “best-fit“ algorithm in order to align the scan of the conventional with the digital impressions. The distances between each preparation margin and the adjacent gingival tissue were measured. Four measures were taken, two interproximally and buccally, for a total of six measures of each abutment considering three modes of impressions. The data were statistically evaluated using two-way analysis of variance (ANOVA) for each site and the Bonferroni test. Results: there was no difference between the two kinds of impression in Group A in both sites, in Group B a difference of 0.483 mm and 0.682 mm at interproximal and buccal sites, respectively, and in Group C 0.750 mm and 0.964 mm at interproximal and buccal sites, respectively. The analysis performed on a site level (mesial/distal/vestibular) for the depth of both vertical preparations revealed significant differences (p < 0.0001). After a post hoc analysis (Bonferroni), vestibular sites of the shallow vertical preparations resulted in significantly lower values compared to the other sites prepared deeply. Conclusions: the results showed that the location of the margin is an important factor in making a precise and complete impression when IOS (Intra Oral Scanner) is used. Moreover, deep preparation into the sulcus is not recommended for IOS (Intra Oral Scanner) impressions.

Cagidiaco, E.F., Zarone, F., Discepoli, N., Joda, T., Ferrari, M. (2021). Analysis of the reproducibility of subgingival vertical margins using intraoral optical scanning (Ios): A randomized controlled pilot trial. JOURNAL OF CLINICAL MEDICINE, 10(5), 1-10 [10.3390/jcm10050941].

Analysis of the reproducibility of subgingival vertical margins using intraoral optical scanning (Ios): A randomized controlled pilot trial

Discepoli N.;Ferrari M.
2021-01-01

Abstract

Background: The aim of this randomized controlled trial was to evaluate the capability of an IOS (Intra Oral Scanner) device, used in standardized conditions, to detect margins of abutments prepared with knife-edge finishing line located at three different levels in relation to the gingival sulcus. Methods: sixty abutment teeth for treatment with full crowns were selected and randomly divided in three groups accordingly to the depth of the finishing line: Group A: supragingival margin; Group B: 0.5–1.0 mm into the sulcus; Group C: 1.5–2.0 mm into the sulcus. Temporary crowns were placed for two weeks and then digital impressions (Aadva IOS 100, GC, Japan) were made of each abutment. As controls, analog impressions were taken, poured, and scanned using a laboratory scanner (Aadva lab scanner, GC, Japan). Two standard tessellation language (STL) files were generated for each abutment, subsequently processed, and superimposed by Exocad software (Exocad GmbH, Darmstadt, Germany), applying the “best-fit“ algorithm in order to align the scan of the conventional with the digital impressions. The distances between each preparation margin and the adjacent gingival tissue were measured. Four measures were taken, two interproximally and buccally, for a total of six measures of each abutment considering three modes of impressions. The data were statistically evaluated using two-way analysis of variance (ANOVA) for each site and the Bonferroni test. Results: there was no difference between the two kinds of impression in Group A in both sites, in Group B a difference of 0.483 mm and 0.682 mm at interproximal and buccal sites, respectively, and in Group C 0.750 mm and 0.964 mm at interproximal and buccal sites, respectively. The analysis performed on a site level (mesial/distal/vestibular) for the depth of both vertical preparations revealed significant differences (p < 0.0001). After a post hoc analysis (Bonferroni), vestibular sites of the shallow vertical preparations resulted in significantly lower values compared to the other sites prepared deeply. Conclusions: the results showed that the location of the margin is an important factor in making a precise and complete impression when IOS (Intra Oral Scanner) is used. Moreover, deep preparation into the sulcus is not recommended for IOS (Intra Oral Scanner) impressions.
2021
Cagidiaco, E.F., Zarone, F., Discepoli, N., Joda, T., Ferrari, M. (2021). Analysis of the reproducibility of subgingival vertical margins using intraoral optical scanning (Ios): A randomized controlled pilot trial. JOURNAL OF CLINICAL MEDICINE, 10(5), 1-10 [10.3390/jcm10050941].
File in questo prodotto:
File Dimensione Formato  
Analysis of The Reproducibility-Discepoli-2021.pdf

accesso aperto

Descrizione: Articolo
Tipologia: PDF editoriale
Licenza: Creative commons
Dimensione 2.39 MB
Formato Adobe PDF
2.39 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11365/1190707